Skip to main content
Üsküdar / İstanbul
Ionpure

Ionpure DC3, DCR and G4 Power Supplies

Ionpure DC power supplies and controllers for CEDI modules: three-phase DC3 (0-600 VDC, 15 A), single-phase DCR (five selectable current ranges) and G4 (600 VDC, 13.2 A).

Send us your requirement

Ionpure DC3, DCR and G4 Power Supplies — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Ionpure power supply unit with a white front cover and green terminal connectors
DC3 input380-480 VAC (auto-ranging, operating range 323-528 VAC), three-phase (L1/L2/L3/ground), 45-65 Hz auto-ranging; power factor 0.92 at full load
DC3 output0-600 VDC, 0.1-15 A DC; current regulation ±150 mA; 3750 VAC isolation between input and output
DC3 installationDirect connection to line power, no isolation transformer required; fully enclosed touch-safe (IP20) housing with heat-sink chassis and dual fan cooling
DC3 communicationMODBUS TCP over Cat5+ Ethernet; USB programming port (PC or thumb drive); 4-20 mA analog current and voltage retransmit
DC3 parallelingWith the optional paralleling board (IP-PB600V45A-1), up to 3 DC3 units can be combined for 45 A DC at 600 VDC
DC3 physical and environment8.61 kg; 22.71 × 34.32 × 16.51 cm (W × H × D); 0-50 °C operating, -15-70 °C storage, altitude below 6000 ft (about 1830 m), 5-95% relative humidity (non-condensing)
DC3 order codeIP-DC3PH600V-M1: three-phase, 0-600 V, 0-15 A DC power supply
DCR input24-600 VAC (UL) / 24-660 VAC (CE), single-phase, 45-65 Hz auto-ranging; the control electronics need a 24 VDC, 0.1 A supply
DCR output and current ranges20-600 VDC output, 0-15 A; five selectable current ranges: 0-2.5 / 0-4.0 / 0-6.5 / 0-10.0 / 0-15.0 A
DCR communicationMODBUS RTU (RS-485) or 4-20 mA analog (0-5 VDC on the retrofit version); 2 × RJ-45 connections; addressing with a 16-position rotary dial
DCR versionsIP-DCR600V15A-M: DIN rail mounted, digital/MODBUS; IP-DCR600V15A-R2: analog (0-5 VDC) retrofit version that replaces legacy G2 controllers (no fieldbus)
DCR physicalDIN rail version (M): 3.56 × 15.24 × 13.24 cm (W × H × D); retrofit version (R2): 10.16 × 15.24 × 13.56 cm; fully enclosed touch-safe design, heat sink and natural convection cooling
DCR environment0-50 °C operating, -15-70 °C storage, altitude below 6000 ft (about 1830 m), relative humidity below 95% (non-condensing)
G4 input220-660 VAC, single-phase, 45-65 Hz auto-ranging; used with an isolation transformer
G4 outputNominal 600 VDC, 13.2 A; maximum DC output voltage is 90% of the AC input voltage; five current ranges selected with a DIP switch: 0-2.5 / 0-4 / 0-6.5 / 0-10 / 0-13.2 A
G4 communication and addressingMODBUS TCP on the Ethernet fieldbus ports (G4-M); station ID 0-9/A-F set with a rotary switch, IP range 192.168.0.200-215, central monitoring of 1-16 units from one panel
G4 control and I/OSetpoint from the IONPURE Touch Panel Display (Ethernet) or a 4-20 mA analog input; the dry ENABLE contact (P1-3/P1-4) must be closed for the output to run; 4-20 mA current and voltage retransmit and a status relay (P1-11/P1-12)
G4 versions and programmingIP-POWER-G4-M (standard) and IP-POWER-G4-R (retrofit); programmed with the Power Panel software over USB-C
G4 certificationCE marked; manufactured in the USA
Common monitoring accessory4.3-inch touch panel display (IP-POWERDSP-TP) that can monitor and control 1 to 16 DCR units; not compatible with the retrofit R2 version, which needs the G2 display (IP-POWERDSP-G2)

Ionpure DC3, DCR and G4 are DC power supplies and controllers that give Ionpure continuous electrodeionization (CEDI) modules a stable direct current. The DC3 is a three-phase unit for 0-600 VDC and 0-15 A, the DCR is a compact single-phase rectifier with five selectable current ranges, and the G4 is a single-phase power controller for 600 VDC and 13.2 A. As Ionpure’s OEM partner in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies these power supplies together with the modules and provides application consulting on selection, panel integration and commissioning.

Replacement modules · Power supply retrofit (G1/G2 → DCR/G4) · Chemical cleaning → Service and replacement module guide | Send us your requirement

Ionpure DC power supplies compared

Power supplyAC inputDC outputCommunication / controlCompatible Ionpure modules
DC3 (IP-DC3PH600V-M1)380–480 VAC · three-phase (no isolation transformer required)0–600 VDC · 0.1–15 A (3 units in parallel: 45 A)MODBUS TCP (Ethernet), USB, 4–20 mA retransmitIonpure CEDI and NEXED EDR modules; the 600 V DC3 can be used with all LX and VNX models
DCR-M (IP-DCR600V15A-M)24–600 VAC (UL) / 24–660 VAC (CE) · single-phase (+24 VDC control supply)20–600 VDC · five current ranges (2.5 / 4.0 / 6.5 / 10.0 / 15.0 A)MODBUS RTU (RS-485) or 4–20 mAMX, LX and VNX CEDI modules and NEXED EDR modules
DCR-R2 (IP-DCR600V15A-R2)24–600 VAC (UL) / 24–660 VAC (CE) · single-phase20–600 VDC · five current ranges up to 15.0 A0–5 VDC analog (replaces legacy G2 and PCB power controllers)MX, LX and VNX CEDI modules and NEXED EDR modules
G4 (IP-POWER-G4-M / G4-R)220–660 VAC · single-phase (with isolation transformer)Nominal 600 VDC · five current ranges (2.5 … 13.2 A)MODBUS TCP (G4-M) or proprietary G2 protocol (G4-R), USB-C, 4–20 mA (G4-M) or 0–5 VDC (G4-R)MX, LX and VNX CEDI modules; the G4-R retrofits G1, G2 and DCR-R controllers

All Ionpure CEDI modules (LX, MX, VNX) and NEXED EDR modules need an external DC power supply to operate. For the module side, see the Ionpure LX series, the Ionpure MX series and the Ionpure VNX series.

DC3: three-phase power supply

The DC3 (IP-DC3PH600V-M1) combines microprocessor-controlled DC power processing, built-in electrical isolation and MODBUS TCP communication. It connects directly to a 380-480 VAC three-phase line without a separate isolation transformer and delivers 0-600 VDC at 0-15 A DC. The fully enclosed, touch-safe (IP20) housing has a heat-sink chassis and dual fans. For NEXED EDR applications that need higher amperage, an optional paralleling board combines up to 3 DC3 units for 45 A DC at 600 VDC. Over MODBUS TCP-Ethernet, an unlimited number of power supplies can be monitored in a daisy chain from a central location, and constant current, voltage or power control can be programmed from an external HMI or PLC.

DCR: compact rectifier for single modules and retrofits

The DCR is a compact single-phase DC power rectifier designed to power MX, LX and VNX CEDI modules and NEXED EDR modules. It works with 24-600 VAC (UL) or 24-660 VAC (CE) input and delivers 20-600 VDC with five selectable current ranges, from 0-2.5 A up to 0-15 A, so the current limit can be matched to the module size. There are two versions: the DIN rail version (IP-DCR600V15A-M) is the digital version for PLC/HMI integration over MODBUS RTU or 4-20 mA, and the retrofit version (IP-DCR600V15A-R2) replaces legacy G2 controllers directly with a 0-5 VDC analog interface, so existing power panels can be upgraded one by one or all at once. The DCR includes soft start protection and on-board diagnostics, and a 4.3-inch touch panel can monitor and control 1 to 16 DCR units.

G4: single-phase controller

The G4 (operation and maintenance manual IP-MAN-G4-0325-EN, March 2025) is a single-phase power controller for 220-660 VAC input with a nominal output of 600 VDC and 13.2 A. It must be fed through an isolation transformer, and the maximum DC output voltage is about 90% of the AC input voltage. A DIP switch on the front panel selects one of five current ranges (0-2.5 / 0-4 / 0-6.5 / 0-10 / 0-13.2 A), and a rotary switch assigns each unit a station ID from 0-9/A-F, which allows central monitoring of 1 to 16 units from a single touch panel over MODBUS TCP in the 192.168.0.200-215 IP range. The setpoint can come from the IONPURE Touch Panel Display (Ethernet) or from a 4-20 mA analog signal, and the unit does not run without a dry ENABLE contact on terminals P1-3 and P1-4. It is programmed through the USB-C interface with the Power Panel software. Two models are offered: the standard IP-POWER-G4-M and the IP-POWER-G4-R retrofit version for legacy G1, G2 and DCR-R panels. The G4 also logs CEDI module electrical resistance and alerts when cleaning may be required.

Which power supply suits which module

The choice depends on the number of modules, the total current and voltage required and the available electrical supply (single-phase or three-phase). The DC3 is three-phase and supplies up to 15 A at 600 VDC, or 45 A with the paralleling accessory; the DCR and G4 are single-phase. The 600 V DC3 can be used with all LX and VNX models. When upgrading legacy G1, G2 or DCR-R panels, the retrofit versions (DCR-R2 or G4-R) are used. For the selection of a complete EDI system, see EDI system selection.

Applications

  • Three-phase DC power (DC3) for Ionpure CEDI and NEXED EDR modules, including VNX and LX
  • Stable current, voltage or power control for CEDI and NEXED EDR modules (DC3)
  • Compact DIN rail power control for MX, LX and VNX modules and NEXED EDR modules (DCR-M)
  • Analog or digital retrofit of legacy G2 controller panels with the DCR-R2 or G4-R
  • PLC/HMI integration over MODBUS RTU or TCP or 4-20 mA

Send us your requirement for Ionpure DC3, DCR and G4 Power Supplies

Describe your application; we will help you identify the right model and configuration.

Call Quote