Skip to main content
Üsküdar / İstanbul
INDUSTRIAL & PROCESS ANALYTICS HUB

Online Measurement and Automation Systems

We bring everything from instant monitoring to alarmed automation for the critical parameters in your water and process lines together in a single system. Hamilton process sensors, Walchem controllers, Pyxis optical sensors, Wenglor fluid sensors, and Heyl Testomat analyzers provide continuous measurement in boiler, cooling tower, bioprocess, wastewater, and pure water lines, connecting directly to PLC and automation systems.

Get a technical quote for Online Measurement and Automation Systems — describe your application; we’ll help you identify the right model and configuration together.

Request a Quote
MEASURED PARAMETERS & PROCESS MONITORING

Analytical Solutions by Parameter

Select the parameter you want to monitor in your process line to see sensor, analyzer, and controller configurations.

0–14 pH

pH

Walchem W100W/Intuition controllers and Hamilton EasyFerm/Polilyte process sensors for pH monitoring and dosing control.

System & Sensor Details →
0.055 µS – 2 S/cm

Conductivity

Walchem contacting/toroidal sensors and Hamilton Conducell (incl. USP 645 compliant UPW) for conductivity measurement.

System & Sensor Details →
0.004–20 mg/L & Trace ppb

Dissolved Oxygen (DO)

Hamilton optical (VisiFerm/VisiWater) and amperometric (OxyFerm/Oxysens) sensors, Pyxis ST-772, and Hefer OD-3000C analyzer.

System & Sensor Details →
0–20 ppm Cl₂

Free Chlorine

Walchem amperometric disinfection sensors, Pyxis combined optical chlorine sensor, and Hefer CL series analyzer.

System & Sensor Details →
0.01–20 ppm ClO₂

Chlorine Dioxide (ClO₂)

ClO₂ residual monitoring with amperometric sensors; Testomat 2000 colorimetric measurement alternative.

System & Sensor Details →
0.01–20 ppm O₃

Ozone (O₃)

Hefer O3-3000C potentiostatic analyzer for real-time ozone control in pure water tanks and disinfection lines.

System & Sensor Details →
0.05–25 °dH

Water Hardness

Heyl Neomeris Testomat series automatic titration analyzers (EVO, 2000, 808, LAB) with scale breakthrough alarm.

System & Sensor Details →
p & m Value (KS4.3)

Carbonate Hardness / Alkalinity

Testomat ECO C and Titromat KH for p/m value acid capacity and boiler alkalinity titration.

System & Sensor Details →
0.001–10,000 NTU

Turbidity & TSS (NTU)

Pyxis LT-73X ultra-low turbidity and ST-730 inline optical probes; nephelometric 90° light scattering technology.

System & Sensor Details →
0.1–10 ppm F⁻

Fluoride (F⁻)

Hefer F-3000C online ISE analyzer for fluoride monitoring in drinking water and industrial wastewater discharge lines.

System & Sensor Details →
Reagent-Free Spectrometer

COD / UV254 / Spectrometry

Instant COD, BOD and TOC determination with the TriOS OPUS / LISA spectral immersion probe, without consuming chemical reagents.

System & Sensor Details →
Fe, PO₄, Br, Polymer

Iron, Phosphate, Bromine, Polymer

Corrosion inhibitor and feedwater chemical tracking in cooling circuits with the Testomat 2000 photometric platform.

System & Sensor Details →
Boiler Feed & Turbine

Silica (SiO₂)

Testomat 808 SiO₂ version; silica breakthrough alarm for steam boilers, turbine feedwater, and pure water deionization.

System & Sensor Details →
Bioreactor Arc®

Viable & Total Cell Density

Hamilton InCyte capacitance (viable biomass) and Dencytee NIR optical (total cell) bioreactor sensors.

System & Sensor Details →
-1...600 Bar Stainless

Pressure Sensors

Wenglor UniBar 1.4404 stainless steel electronic pressure sensors (-1…600 bar) and OLED display transmitters.

System & Sensor Details →
-50...200 °C

Temperature Sensors

Wenglor UniTemp 1.4404 stainless steel immersion sensors (0…140 °C; 0…200 °C variant) and weFlux² IO-Link temperature sensors (-50…200 °C).

System & Sensor Details →
10...400 cm/s Calorimetric

Flow & Flow Rate Sensors

Wenglor weFlux² and UniFlow calorimetric stainless steel flow sensors; orientation-independent mounting and dry-run protection.

System & Sensor Details →
General & Pitting MPY

LPR Corrosion Rate Sensor

Pyxis CR series LPR sensors for simultaneous inline tracking of general corrosion (mpy) and pitting corrosion.

System & Sensor Details →
PTSA Fluorometer & Brix

PTSA Fluorometer & Refractometer

Pyxis PTSA/fluorescein fluorometers for chemical dosing verification; RT-100 inline digital refractometer.

System & Sensor Details →
Walchem Multi-Parameter

Cooling Tower Automation

Full integration of blowdown, biocide, inhibitor, and corrosion management with Walchem Intuition-9/6 and W100W controllers.

System & Sensor Details →
Automatic Blowdown & Condensate

Boiler, Condensate & Steam Generator

Scale and corrosion prevention in boiler piping with high-temperature conductivity probes, automatic blowdown valves, and a hardness alarm.

System & Sensor Details →
Condensate Oil Leak Alarm

Oil in Water & Hydrocarbon (PAH)

TriOS enviroFlu-HC UV fluorometer and Pyxis HM-900 handheld analyzer; oil leak monitoring in condensate recovery and cooling water.

System & Sensor Details →
Optoelectronic Analyzer

Copper and Nickel Plating Systems

Precise concentration tracking in electroless plating baths with Walchem Intuition-6 Copper/Nickel (WCU6/WNI6) photometric controllers.

System & Sensor Details →
SENSOR + CONTROLLER = ANALYZER

Analyzer or sensor? Which one do you need

The sensor measures, the controller decides. The sensor reads the value in the process; the controller compares this value against the setpoint, generates an alarm, and drives the dosing pump or valve. What the market commonly calls an "analyzer" is often exactly this: sensor + controller. If you're looking for a "pH analyzer," what you actually need is a pH sensor paired with a suitable controller — we supply both together, matched to each other.

Choosing a controller doesn't limit your sensor choice: thanks to their universal sensor input and analog input, the Intuition-6 and Intuition-9 work with practically the full range of sensors on the market. The table below shows our recommended sensor–controller pairing for each parameter.

PARAMETER → SENSOR → CONTROLLER

Recommended Sensor and Controller Pairings

Measured Parameter Recommended Sensor Recommended Controller
pH / ORP Hamilton EasyFerm Plus, Polilyte Plus, ChemoTrode · Walchem WEL/WDS Intuition-6 · W100W · W600
Conductivity Hamilton Conducell · Walchem contacting and toroidal Intuition-6 · W100W · W600
Dissolved oxygen Hamilton VisiFerm DO · Pyxis ST-772 · Hefer PME Intuition-6 · Intuition-9 · Hefer OD-3000C
Dissolved carbon dioxide Hamilton CO₂NTROL Intuition-6 · Intuition-9
Chlorine · chlorine dioxide · ozone Hefer PME potentiostatic · Walchem amperometric Intuition-6 · Intuition-9 (with 2030 transmitter) · Hefer 3000-C series
Water hardness Hefer WHA-2000 ISE electrode Intuition-6 · Intuition-9 · Hefer WHA-3000-C · Testomat (ready-made analyzer)
Turbidity Hefer TU-311 / TU-341 (loop-powered) Intuition-6 · Intuition-9 · Hefer TSS-3000C
Cell density · Brix Hamilton InCyte · Dencytee · Pyxis RT-100 (Brix) Intuition-6 · Intuition-9
COD · SAC254 · nitrate TriOS OPUS · LISA-254 · NICO Intuition-6 · Intuition-9 · TriBox

You don’t need a separate analyzer for every parameter

Hefer sensors connect in two ways:

(a) Ready-made analyzer — PME electrode + its own controller: CL-3000-C (chlorine), CLO-3000-C (chlorine dioxide), O-3000-C (ozone), WHA-3000-C (hardness), OD-3000C (oxygen). One parameter, one box.

(b) Transmitter to a single hub — PME electrode + 2030 series transmitter (PH-2030 (pH), MV-2030 (ORP), C-2030 (conductivity), CL-2030 (chlorine / dissolved ozone)) generates a 4-20 mA signal; this signal connects to an analog input card fitted to the Intuition-6 or Intuition-9.

In other words, instead of four separate analyzers for four parameters, you get four transmitters and a single controller.

How many parameters will you measure?

  • W100W — entry level, wall-mounted: conductivity and pH.
  • Intuition-6 — 6 relay outputs, universal sensor input; expandable with analog, Modbus, and combination cards.
  • Intuition-9 — 24 sensor inputs, 12 relays, color touchscreen; the same card architecture.
  • W600 — network-connected; conductivity, pH, ORP, and disinfectant.

Card architecture: the Intuition-6 and Intuition-9 are modular — sensor input, analog (4-20 mA), Modbus, and combination cards are selected according to the application. This is why the controller can practically work with the full range of sensors on the market: any missing connection type is simply added with a card.

The W900 has been discontinued; the Intuition-9 replaced it.

If you want a ready-made analyzer in a single box

Hefer CL / CLO-3000-C / O-3000-C / WHA · Testomat EVO TH, LAB, 808, ECO · TITROMAT carbonate + total hardness · Heyl Neomeris · TriOS EGC Water Analyzer.

TECHNICAL SELECTION GUIDE

Measurement & Automation Comparison Matrices

Determine whether your process line needs continuous inline control or portable handheld field analysis, and identify the most suitable controller model.

CONCEPT COMPARISON

Inline Process Sensors (Pyxis ST / Hamilton / Walchem) vs Portable Handheld Devices (Pyxis SP Series)

Criterion Inline Process Sensors (ST-500, ST-772, Arc®, WDS) Portable Handheld Analyzers (SP-910, SP-710B, SP-200)
Measurement Frequency Continuous, Uninterrupted Measurement (1 reading per second, instant response) Spot / Periodic Testing (Manual measurement as needed)
Control & Dosing Integration Fully Automatic: drives dosing pumps and blowdown valves directly via 4–20 mA and Modbus RS-485. Manual Reporting: generates and archives PDF/CSV reports via the uPyxis® mobile app.
Installation & Piping Requirements Fixed installation via a pipeline tee fitting, bypass flow cell, or immersion housing. Zero Installation: carried in a case, battery-powered, taken to any point in the field.
Sampling Requirement No sampling required; measures directly inside the flowing pressurized line. Measured in the field from a sample bottle (SP-910: 25 mL bottle; the colorimetric method's set reaction time, or a direct reading for PTSA/fluorescein/turbidity).
Primary Use Case Process automation, limit-exceedance alarms, and continuous prevention of chemical waste and scaling. Field audits, cross-calibration verification of inline sensors, and incoming chemical shipment acceptance testing.
CONTROLLER MATRIX

Comparison of Walchem Multi-Parameter Water Treatment Controllers

Model Sensor Inputs Relay & Analog Outputs Communication & IoT Recommended Application
Intuition-9 (Flagship) 4 I/O slots: up to 8 direct sensor inputs (pH, conductivity, DO, disinfection, etc.) and up to 24 analog (4-20 mA) inputs (model-dependent) 12 relay outputs + 8 isolated 4-20 mA outputs Ethernet, Wi-Fi, Modbus TCP/IP, BACnet, Walchem Fluent® Large-scale industrial cooling towers, boiler rooms, and multi-point disinfection facilities.
Intuition-6 (Mid-range) 0–2 sensor inputs + 0–2 analog (4-20 mA) inputs (model-dependent) 6 relay outputs + 2 isolated 4-20 mA outputs Ethernet (optional BACnet, Modbus TCP/IP), Walchem Fluent® Mid-sized cooling towers (WCT), steam boilers (WBL), and dual-parameter pH/ORP processes.
W600 Series Up to 4 sensor / analog inputs with 2 input cards 6 relay outputs Ethernet, Modbus TCP/IP, USB data logging Single- or dual-line water conditioning, wastewater neutralization, and corrosion monitoring.
W100 Series (Compact) 1 direct sensor input (pH, ORP, or conductivity) 3 relay outputs + 1 x 4-20 mA output Compact LCD display, simple menu Small cooling towers, single boiler blowdown control, neutralization tanks, and OEM panels.
TITRATOR MATRIX

Heyl Testomat® & Neomeris Online Water Hardness and Alkalinity Instruments

Model Measurement Parameter & Range Measurement Principle Outputs & Data Application
Testomat 2000® Total Hardness: 0.05 – 25.0 °dH
Carbonate Hardness: 0.5 – 20.0 °dH
Automatic Colorimetric Titration (DIN 38409) 2 limit relays; optional 4–20 mA (SK910) and RS-232 (RS910) cards Reverse osmosis (RO) pretreatment, steam boiler feedwater, and commercial water softening systems.
Testomat EVO® Total Hardness: 0.05 – 25.0 °dH (depending on indicator type) Precision Titration with Piston Dosing Pump Graphic LCD, SD card logging, RS232, 0/4–20 mA, 2 limit relays Industry 4.0-ready modern power plants, pharmaceutical facilities, and SCADA-integrated processes.
Titromat® Carbonate Hardness (KH): 0.7 – 53.6 mmol/L (reagent-dependent)
Total Hardness (TH) and residual m-value (M1/M2)
Automatic Two-Reagent Titration 2 limit contacts, 0/4–20 mA output Boiler water corrosion control, cooling water acid conditioning, and decarbonization plants.
Testomat 808® Total Hardness: 0.02 – 5.0 °dH Compact Indicator-Based Limit Control Relay alarm contact + 4-20 mA Safety interlock ahead of boilers and reverse osmosis; instantly detects resin exhaustion.
ANALYTICAL MEASUREMENT & AUTOMATION FAQ

Frequently Asked Questions About Online Measurement and Instrumentation

A technical guide to sensor selection, fouling compensation, Memosens digital technology, and automatic controller architectures.

How is the PTSA fluorometer (Pyxis ST-500) unaffected by turbidity and suspended solids in tower water?

The Pyxis ST-500 and ST-500SS probes use a proprietary multi-channel optical design. The device simultaneously measures fluorescence emission and turbidity scatter, mathematically compensating for background color and sediment interference. According to the manufacturer, measurement performance is maintained up to 100 NTU turbidity and/or 5 ppm iron, providing a stable tracer reading across the 0–300 ppb PTSA range.

Which process parameters can be managed simultaneously with the Walchem Intuition-9 controller?

With up to 8 direct sensor inputs and up to 24 analog inputs, the Intuition-9 controller manages pH, ORP, contacting/toroidal conductivity, dissolved oxygen (DO), free/total chlorine, corrosion rate (LPR) and flow parameters from a single screen. Blowdown valves, biocide pumps, and antiscalant dosing are closed-loop controlled through its 12 relay outputs.

What are the key differences between the Heyl Testomat 2000 and Testomat EVO?

The Testomat 2000 is a well-established, industry-standard water hardness titrator with 2 limit relays and optional 4-20 mA / RS232 cards. The Testomat EVO is the successor to the Testomat ECO, offering precision titration with a piston dosing pump, a graphic LCD, SD card data logging, and an RS232 serial interface; its 0.05–25 °dH range is selected according to indicator type.

What advantages do Hamilton Arc® / Memosens digital sensors have over conventional analog electrodes?

Hamilton Arc® sensors carry the microprocessor inside the sensor body, converting the measured analog millivolt signal directly into digital data at the sensor head. They are completely unaffected by moisture, cable length, or electromagnetic interference (motor/frequency inverter noise). Because the sensor also stores its calibration data in memory, it can be pre-calibrated in the laboratory and then installed on-site as a plug-and-play unit.

Does the Hefer WHA-3000-C ion-selective (ISE) hardness system consume reagents?

No. The Hefer WHA-3000-C and WHA-2000 ISE electrode system operates on a completely reagent-free (no chemical consumption) potentiometric ion-selective principle. It measures Ca²⁺ and Mg²⁺ ions in as little as 30 seconds without consuming any titration reagent or indicator.

Let’s Select the Right Measurement Instrument for Your Process Together

Share your sample temperature, line pressure, conductivity range, and communication protocol requirements; drawing on 25+ years of field experience, we’ll design the right sensor and controller combination for you.

Call Us