Ionpure LX Series CEDI Modules
Ionpure LX Series (LX-Z, LX-X, LX-EU, LX-HI) are industrial CEDI modules for continuous deionized water production without chemical regeneration, from 0.22 to 10 m³/h per module.
Send us your requirementIonpure LX Series CEDI Modules — describe your application and we will help you identify the right model and configuration together.
Technical specifications

| Module variants | LX-Z (industrial), LX-X (high purity), LX-EU (for use in the European Union), LX-HI (hot water sanitizable) |
|---|---|
| LX-Z flow | 0.22-10 m³/h per module; seven models from LXM04Z to LX8000Z |
| LX-Z electrical and performance | 0-400 VDC, 1.0-6.0 A DC; recovery 90-95%; silica removal 90-99%, depending on feed conditions |
| LX-Z chlorine tolerance and materials | Feed water chlorine tolerance up to 0.05 ppm (total Cl2); wetted materials comply with NSF 14 and NSF 61 requirements |
| LX-X flow | 0.22-7.67 m³/h per module; six models from LXM04X to LXM45X |
| LX-X electrical and purity | 0-300 VDC, 1.0-6.0 A DC (the 600 V DC3 power supply can be used with all LX models); product water resistivity >17 MΩ·cm at minimum flow, >15 MΩ·cm at nominal flow and >7 MΩ·cm at maximum flow, based on the maximum feed conductivity equivalent of 40 µS/cm |
| LX-X materials | Wetted materials comply with NSF 61 requirements |
| LX-EU flow and electrical | 0.22-7.67 m³/h per module; 0-300 VDC, 1.0-6.0 A DC |
| LX-EU materials | Wetted materials comply with US FDA 21 CFR and with EC directives on materials in contact with foodstuffs |
| LX-HI sanitization | Hot water sanitization at 85 °C ± 5 °C and 2.0 bar; no ramp up or down required; performance proven after more than 150 sanitizations |
| LX-HI operating temperature and electrical | Continuous operation up to 60 °C; 0-600 VDC, 0-10 A DC; product water conductivity <0.1 µS/cm |
| LX-HI materials | Wetted materials comply with FDA requirements |
| Common feed water conditions | Conductivity equivalent <40 µS/cm (including CO2 and silica), RO permeate source, pH 4-11, total hardness <1.0 ppm (as CaCO3), TOC <0.5 ppm, silica <1.0 ppm |
| Feed water chemical limits | Total chlorine (Cl2) <0.02 ppm for LX-X, LX-EU and LX-HI and <0.05 ppm for LX-Z; iron, manganese and sulfide <0.01 ppm each |
| Design and pressure | Double O-ring seal; inlet pressure up to 6.9 bar; maximum ambient temperature 45 °C |
| Certifications | CE marked; manufactured in an ISO 9001 and ISO 14000 quality and environmental management system; the LX-X, LX-EU and LX-HI datasheets state manufacture in accordance with IFANCA Halal standards |
Ionpure LX Series modules are industrial continuous electrodeionization (CEDI) modules that produce deionized water continuously, without downtime or chemical regeneration. The family has four variants: LX-Z for industrial deionized water, LX-X for high-purity applications, LX-EU for use in the European Union and LX-HI, which can be sanitized with hot water. As Ionpure’s OEM partner in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies replacement LX-Z, LX-X, LX-EU and LX-HI modules and provides application consulting on module replacement, chemical cleaning (CIP) and commissioning.
Replacement modules · Module renewal · Chemical cleaning → Service and replacement module guide | Send us your requirement
All variants need the same basic feed water (RO permeate with a conductivity equivalent below 40 µS/cm). For an overview of all Ionpure CEDI modules, see EDI / CEDI systems; for smaller laboratory-scale flows see the Ionpure MX series, and for larger single-module flows the Ionpure VNX series.
Ionpure LX sizes compared
| Model size | Nominal flow, LX-X (m³/h) | Flow range, LX-X (m³/h) | Max. DC voltage, LX-Z / LX-X / LX-EU (1 – 6 A) | Max. DC voltage, LX-HI (1 – 10 A) |
|---|---|---|---|---|
| LXM04 | 0.45 | 0.22 – 0.68 | 27 VDC | 50 VDC |
| LXM10 | 1.13 | 0.57 – 1.70 | 67 VDC | 125 VDC |
| LXM18 | 2.04 | 1.02 – 3.06 | 120 VDC | 225 VDC |
| LXM24 | 2.73 | 1.36 – 4.09 | 160 VDC | 300 VDC |
| LXM30 | 3.40 | 1.70 – 5.11 | 200 VDC | 375 VDC |
| LXM45 | 5.11 | 2.57 – 7.67 | 300 VDC | 600 VDC |
Note: Flow values are from the LX-X datasheet (ION-LXX-DS-0620); the LX-EU datasheet lists the same six sizes with the same flow values, while LX-Z and LX-HI flow values differ slightly (see the datasheets). LX-Z adds a seventh size, the LX8000Z (also listed as LXM55Z), for a flow of up to 10 m³/h and a maximum of 400 VDC at 1 – 6 A. DC voltage limits are from manual IP-MAN-LX-0426 (Table 2-2). The 600 V DC3 power supply can be used with all LX models; the DCR power supply can also be used but requires correctly sized isolation transformers.
LX-Z and LX-X: industrial series
LX-Z is designed for industrial deionized water applications such as boiler makeup water for power plants and water for hydrocarbon and chemical processing (HPI/CPI). Its seven models cover 0.22-10 m³/h per module at 0-400 VDC and 1.0-6.0 A DC, with 90-95% recovery and 90-99% silica removal depending on feed conditions. The improved chlorine tolerance allows up to 0.05 ppm total chlorine in the feed water.
LX-X produces deionized water for a wide range of high-purity applications, including boiler makeup water for power plants, pharmaceutical pure water and HPI/CPI. The LXM04X to LXM45X models cover 0.22-7.67 m³/h per module at 0-300 VDC and 1.0-6.0 A DC. Product water resistivity is above 17 MΩ·cm at minimum flow, above 15 MΩ·cm at nominal flow and above 7 MΩ·cm at maximum flow, based on the maximum feed conductivity equivalent of 40 µS/cm.
LX-EU: the variant for use in the European Union
LX-EU has the same size range as LX-X: 0.22-7.67 m³/h per module at 0-300 VDC and 1.0-6.0 A DC. It is intended for boiler makeup water, pharmaceutical pure water and HPI/CPI applications in the European Union. Its wetted materials comply with US FDA 21 CFR and with the EC directives on materials in contact with foodstuffs; the material approvals are listed in Appendix D of the LX manual.
LX-HI: hot water sanitization
LX-HI modules are sanitized with hot water at 85 °C ± 5 °C and a pressure of 2.0 bar, without a ramp up or down, and performance has been proven after more than 150 sanitizations. This applies mainly to pharmaceutical and biotechnology applications and others where chemical-free, instant hot water sanitization is wanted. LX-HI modules can also run continuously at up to 60 °C, which allows use at higher temperatures than typical CEDI, for example in steam generation in power applications. They operate at 0-600 VDC and 0-10 A DC, with product water conductivity below 0.1 µS/cm.
Power supply and module selection
All LX modules need an external DC power supply: see Ionpure DC3, DCR and G4 power supplies. The right LX variant depends on feed water quality, target flow, the region of use (LX-EU for the European Union) and the sanitization requirement (LX-HI). For help with the selection, see EDI system selection; for the technology itself, see what is electrodeionization (EDI).
Applications
- Boiler makeup water for power plants (LX-Z, LX-X, LX-EU)
- Water for hydrocarbon and chemical processing (HPI/CPI)
- Pharmaceutical pure water (LX-X, LX-EU)
- Pharmaceutical and biotechnology applications that need chemical-free hot water sanitization (LX-HI)
- CEDI lines that run at higher temperatures than typical, such as steam generation in power applications (LX-HI)
Datasheets and manuals
- Ionpure LX-Z Series CEDI Modules Datasheet Datasheet · PDF
- Ionpure LX-Z 55 CEDI Module Datasheet Datasheet · PDF
- Ionpure LX Series CEDI Modules Operation and Maintenance Manual User manual · PDF
- Ionpure LX-X Series CEDI Modules Datasheet Datasheet · PDF
- Ionpure LX-X Series CEDI Modules Operation and Maintenance Manual User manual · PDF
- Ionpure LX-EU Series CEDI Modules Datasheet Datasheet · PDF
- Ionpure LX-HI Series Hot Water Sanitizable CEDI Modules Datasheet Datasheet · PDF
- Ionpure LX-HI Series CEDI Modules Operation and Maintenance Manual User manual · PDF
Documents were last compared with the manufacturer's source on 2026-11-03.
Send us your requirement for Ionpure LX Series CEDI Modules