Skip to main content
Üsküdar / İstanbul
Ionpure

Ionpure MX Series CEDI Modules

Ionpure MX Series are low-flow CEDI modules (MX30 to MX500) for laboratory and smaller-scale single-module installations, with 30-500 L/h nominal flow.

Send us your requirement

Ionpure MX Series CEDI Modules — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Ionpure MX series CEDI module family: five white cylindrical modules of increasing length
Model seriesMX30, MX60, MX125, MX250, MX500 for laboratory and smaller-scale single-module installations
Nominal flow30-500 L/h; minimum 15-250 L/h and maximum 45-750 L/h, depending on the model
Electrical requirementMaximum module requirements of 200, 400 or 600 VDC at 2.5 A DC (datasheet); per-model maximum of 27 to 426 VDC at up to 2.5 A DC (manual)
Operating conditionsContinuous operation up to 5 bar feed pressure and 45 °C
Pressure drop0.7-1.4 bar at nominal flow
Recovery and purityRecovery up to 95%; product water resistivity >16 MΩ·cm; silica removal 90-99%, depending on feed water
DesignDouble O-ring seal and housing; proprietary all-filled concentrate compartments that need no recirculation pump or brine injection
Feed water conditionsConductivity equivalent <40 µS/cm (including CO2 and silica); RO permeate source; pH 4-11; total hardness <1.0 ppm (as CaCO3); free chlorine <0.02 ppm
DimensionsDiameter 17.78 cm for all models; length from 18.41 cm (MX30) to 62.96 cm (MX500)
CertificationsCE marked; manufactured in an ISO 9001 and ISO 14000 quality and environmental management system

Ionpure MX Series modules are low-flow continuous electrodeionization (CEDI) modules for laboratory and smaller-scale applications. Five models, MX30, MX60, MX125, MX250 and MX500, cover a nominal flow of 30 to 500 L/h, which suits single-module installations. As Ionpure’s OEM partner in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies replacement MX30, MX60, MX125, MX250 and MX500 modules, matches them with a DCR power supply and provides application consulting on chemical cleaning (CIP) and maintenance.

Replacement modules · Module renewal · Chemical cleaning → Service and replacement module guide | Send us your requirement

The MX series sits below the LX and VNX families in flow. For an overview of all Ionpure CEDI modules, see EDI / CEDI systems; for higher-flow industrial needs see the Ionpure LX series and the Ionpure VNX series.

Ionpure MX models compared

ModelNominal flow (L/h)Flow range (L/h)Max. FCE (µS/cm)Silica (SiO₂) removalDC requirement (manual IP-MAN-MX, Table 2-1)
MX303015 – 45≤ 4090 – 99%0 – 27 VDC · 0 – 2.5 A
MX606030 – 90≤ 4090 – 99%0 – 53 VDC · 0 – 2.5 A
MX12512562.5 – 187≤ 4090 – 99%0 – 106 VDC · 0 – 2.5 A
MX250250125 – 375≤ 4090 – 99%0 – 213 VDC · 0 – 2.5 A
MX500500250 – 750≤ 4090 – 99%0 – 426 VDC · 0 – 2.5 A

Note: FCE is the feed conductivity equivalent, including CO2 and silica. The datasheet (ION-MXLowFlow-DS-0818) groups the power supply sizing by module length at a maximum of 200, 400 or 600 VDC (2.5 A DC), while the manual gives each model’s own maximum DC voltage (27 to 426 VDC). The actual DC requirement depends on the application and can be calculated with the manufacturer’s projection software.

MX30 to MX500: from laboratory to smaller-scale systems

The five models cover the nominal flow range in steps, from the MX30 (nominal 30 L/h, minimum 15 and maximum 45 L/h) to the MX500 (nominal 500 L/h, minimum 250 and maximum 750 L/h). All models share the same diameter of 17.78 cm; only the length changes, from 18.41 cm for the MX30 to 62.96 cm for the MX500. A double O-ring seal and housing give a leak-free design. The proprietary all-filled concentrate compartments remove the need for a separate recirculation pump or brine injection, which keeps single-module installations simple.

The modules run continuously at up to 5 bar feed pressure and up to 45 °C, with product water resistivity above 16 MΩ·cm and silica removal of 90-99%, depending on the feed water. Recovery is up to 95%.

Electrical supply and power supply selection

Each MX module needs up to 2.5 A DC at 27 to 426 VDC, depending on the model (200, 400 or 600 VDC maximum in the datasheet grouping). The DCR power supply offers a selectable 0-2.5 A current range, and the G4 power controller offers the same range, which matches the MX requirement; both are designed for use with MX, LX and VNX modules. See Ionpure DC3, DCR and G4 power supplies.

Installation and feed water requirements

MX modules should be installed indoors, out of direct sunlight, at an ambient temperature of no more than 45 °C. The feed water must be RO permeate with a conductivity equivalent (including CO2 and silica) below 40 µS/cm, a pH of 4-11 and a total hardness below 1.0 ppm (as CaCO3). The modules are CE marked and manufactured in an ISO 9001 and ISO 14000 quality and environmental management system.

Applications

  • Laboratory and smaller-scale applications
  • Single-module installations
  • Power, HPI/CPI, microelectronics, food and beverage and laboratory applications
  • Installations where a separate recirculation pump or brine injection is not wanted

Datasheets and manuals

Documents were last compared with the manufacturer's source on 2026-11-03.

Send us your requirement for Ionpure MX Series CEDI Modules

Describe your application; we will help you identify the right model and configuration.

Call Quote