Pyxis DW-2100P Series Analyzer

Pyxis DW-2100P is a turn-key panel analyzer for ultra-low turbidity, free chlorine, pH and temperature with a touch screen, in EPA (US) and ISO (EU) versions.

Send us your requirement

Pyxis DW-2100P Series Analyzer — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Measured parametersUltra-low turbidity, free chlorine, pH and temperature, measured at the same time by two Pyxis smart sensors (LT-739 or LT-739B turbidity and ST-765SS-FCL chlorine and pH)
Turbidity channel (DW-2100P-US)Warm white LED light source; dual range 0.001-10 / 10-40.00 NTU; accuracy ±0.005 NTU or 2% (<10 NTU); repeatability ±0.001 NTU or 0.5% (<10 NTU); EPA-180.1 compliant
Turbidity channel (DW-2100P-EU)860 nm infrared LED light source; same dual range and accuracy; ISO-7027 compliant
Free chlorine and pH channelFree chlorine 0.01-5.00 ppm (bare-gold electrochemical method), pH 0.01-14.00; accuracy ±0.01 ppm or 1% of full scale (pH-compensated up to pH 9.0), pH ±0.01
Resolution and responseMinimum resolution 0.001 NTU / 0.01 ppm / 0.01 pH; response 4 s after immersion (turbidity), T95 ≤60 s (free chlorine), T95 ≤5 s (pH)
FR-200 dual-sensor flow reservoir1/4-inch inlet, 20 mm outlet, 1/2-inch drain; minimum inlet pressure 0.05 MPa
Display and communication7-inch color industrial capacitive touch screen; built-in 4 GB storage for about 1 million records; RS-485 Modbus-RTU and RJ-45 Modbus-TCP; 4-20 mA outputs; 96-260 VAC, 50-60 Hz, 10 A fuse, 200 W
Environment and protectionPanel operating temperature 4-45 °C; sample water temperature 4-40 °C; sample pressure 0.05-0.2 MPa; IP65 panel and IP67 sensors; panel 790 × 450 × 235 mm (H × W × D), about 20 kg

The Pyxis DW-2100P is a turn-key, panel-mounted drinking water analyzer that measures ultra-low turbidity, free chlorine, pH and temperature on one 7-inch touch screen. It combines an ultra-low turbidity sensor from the LT-73X family (LT-739 or LT-739B) with the ST-765SS-FCL free chlorine and pH sensor, both housed in one FR-200 dual-sensor flow reservoir and pre-wired to the panel over RS-485 Modbus. Mikron Proses (Üsküdar, Istanbul) provides application consulting on choosing between the two versions for your drinking water, secondary water supply or process water point.

Drinking water · Secondary water supply → Send us your requirement

For background on the measurement, see the guide on turbidity in drinking water; a turbidity-only panel is described on the DW-739 page.

Two versions: US (EPA) and EU (ISO)

The DW-2100P is offered in two versions according to the light source and the standard it follows. The DW-2100P-US uses a warm white LED and complies with EPA-180.1; the DW-2100P-EU uses an 860 nm infrared LED and complies with ISO-7027. In both versions turbidity has a dual range of 0.001-10 / 10-40.00 NTU, accuracy of ±0.005 NTU or 2% (below 10 NTU) and repeatability of ±0.001 NTU or 0.5%. The free chlorine channel is the same in both: 0.01-5.00 ppm by the bare-gold electrochemical method, with ±0.01 ppm or 1% of full scale accuracy, compensated for pH up to 9.0, and the pH channel covers 0.01-14.00 with ±0.01 accuracy. The datasheet states that the chlorine measurement is consistent with DPD wet chemistry and meets EPA 334.0 and ISO 7393.

FR-200 flow reservoir

Both sensors sit in a single FR-200 dual-sensor flow reservoir, designed to calm the sample: air bubbles dissipate, suspended solids settle, and foam or other impurities commonly seen in drinking water influent are removed before the measurement. The minimum inlet pressure is only 0.05 MPa, so the panel suits sampling at the end of pipe networks and in secondary water supply.

Display, data logging and communication

The panel has a 7-inch color industrial capacitive touch screen with built-in 4 GB storage for about 1 million data and event records. Outputs include 4-20 mA analog, RS-485 Modbus-RTU and Modbus-TCP over an RJ-45 socket; a USB host port is used for data download and screen upgrade. Power supply is 96-260 VAC at 50-60 Hz with a 10 A fuse, 200 W.

Which version, US (EPA) or EU (ISO), suits your site depends on the reference standard you use. Send us your requirement and we will select the right version together.

Applications

  • Turn-key monitoring of turbidity, free chlorine and pH in drinking water networks and secondary water supply from one panel
  • Continuous multi-parameter monitoring of decorative and swimming water
  • Quality verification of food and beverage process water