Skip to main content
Üsküdar / İstanbul
Pyxis

Pyxis PRISM RT-110 Series Compact Inline Refractometer

Pyxis PRISM RT-110 and RT-110L are compact inline refractometers that convert refractive index to %BRIX, %MEG and %MPG, for by-pass flow or direct tank installation.

Send us your requirement

Pyxis PRISM RT-110 Series Compact Inline Refractometer — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Measuring rangeRefractive index 1.31700-1.5100; %BRIX 0.00-85.00; mono-ethylene glycol (%MEG) 0.00-100.00; mono-propylene glycol (%MPG) 0.00-100.00; temperature -20 to 80 °C
Resolution and accuracyRefractive index resolution 0.00001, accuracy ±0.0001; %BRIX and glycol resolution 0.01, accuracy ±0.1
Sample temperatureRT-110 (by-pass flow): -20 to 70 °C; RT-110L (tank mounting): -20 to 65 °C
Pressure and flowMaximum sample pressure ≤0.98 MPa; maximum flow below about 51 L/min (both models)
Ambient temperature-10 to 40 °C
Body and size316L stainless steel body, sapphire measuring surface; IP-67 protection; 1 kg; φ64 × 133 mm (both models)
Outputs4-20 mA analog and RS-485 Modbus digital output; wireless access needs the optional MA-CR Bluetooth adapter (no built-in display or built-in Bluetooth)
Power supply24 VDC, 1.5 W
Mounting typesRT-110 (P/N 59207): by-pass sample line with a 3/4-inch NPT flanged stainless steel Tri-Clamp flow cell; RT-110L (P/N 57682): directly on the tank or reservoir wall with a 2.5-inch stainless steel sanitary clamp coupling
Data loggingUp to 56 days of history at 1 reading per minute through the uPyxis app

The Pyxis PRISM RT-110 series is a compact inline digital refractometer that measures the refractive index of a liquid (1.31700-1.5100, ±0.0001 accuracy) and converts it to 0.00-85.00 %BRIX, 0.00-100.00 %MEG (mono-ethylene glycol) or 0.00-100.00 %MPG (mono-propylene glycol). The body is 316L stainless steel with a sapphire optical surface (IP-67, ≤0.98 MPa), and outputs are 4-20 mA and RS-485 Modbus. Mikron Proses (Üsküdar, Istanbul) provides application consulting on choosing between the by-pass (RT-110) and tank (RT-110L) versions.

Glycol and BRIX concentration → Send us your requirement

The series is built on the RT-100 platform and is a stand-alone device that can log live data and provide communication output. For other refractometers from the same maker, see the RT-200 high-temperature refractometer and the RT-50 cutting fluid refractometer.

Two mounting types: RT-110 and RT-110L

The series offers the same measuring core in two mounting designs. The RT-110 (P/N 59207) is installed in a by-pass sample line with a 3/4-inch NPT flanged 316L stainless steel Tri-Clamp flow cell assembly and works at sample temperatures of -20 to 70 °C. The RT-110L (P/N 57682) is installed directly on the wall of a tank or reservoir with a 2.5-inch stainless steel sanitary clamp coupling; its sample temperature range is slightly narrower, -20 to 65 °C. Both models measure refractive index with 0.00001 resolution and ±0.0001 accuracy, and %BRIX and glycol with 0.01 resolution and ±0.1 accuracy, over a measurement temperature range of -20 to 80 °C.

Data center coolant monitoring

The datasheet states that the RT-110 is designed to integrate into data center coolant monitoring systems.

Outputs, calibration and body

The RT-110 series connects to any microprocessor-based controller, display, PLC or DCS network through its integrated 4-20 mA and RS-485 Modbus outputs. The RT-110 series has no built-in display or built-in Bluetooth; wireless access, diagnostics and calibration need the optional MA-CR Bluetooth adapter, which is purchased separately. When connected, the uPyxis app offers air calibration of the refractive index, offset calibration of the liquid concentration, a return to factory settings, history transfer (up to 56 days at 1 reading per minute) and live trend display of refractive index and temperature. Both models have a 316L stainless steel body and sapphire measuring surface, are IP-67, weigh 1 kg and measure φ64 × 133 mm; maximum sample pressure is 0.98 MPa, maximum flow is below about 51 L/min and the supply is 24 VDC (1.5 W). The manufacturer notes that suspended solids in contaminated samples can build up on the optical surface, so the sensor surface should be cleaned regularly, and the optional RT-series ultrasonic cleaning module can be used (for the RT-110L only).

Send us your requirement and we will select the version and accessories together.

Applications

  • Closed-loop cooling systems: mono-ethylene and mono-propylene glycol concentration monitoring
  • Data center coolant monitoring systems (the RT-110 is designed to integrate into them)
  • BRIX and sugar concentration process applications
  • Specific gravity determination through refractive index, also in contaminated sample streams

Datasheets and manuals

Documents were last compared with the manufacturer's source on 2026-09-26.

Other Pyxis products

All Pyxis products →

Send us your requirement for Pyxis PRISM RT-110 Series Compact Inline Refractometer

Describe your application; we will help you identify the right model and configuration.

Call Quote