TriOS FlowCell FC 48/10 USC
TriOS FlowCell FC 48/10 USC is a bypass flow cell with integrated ultrasonic cleaning and a monitoring window for TriOS sensors with an optical path length of up to 10 mm.
Send us your requirementTriOS FlowCell FC 48/10 USC — describe your application and we will help you identify the right model and configuration together.
Technical specifications
| Product type | Bypass flow cell with integrated ultrasonic cleaning |
|---|---|
| Compatible sensors | Sensors with an optical path length of up to 10 mm |
| Housing material | POM (polyoxymethylene) |
| Pressure and flow | Maximum 1 bar, 2-4 L/min |
| Power supply | 12-24 VDC (± 10 %), power consumption ≤ 15 W |
| Trigger input | 5-24 VDC (galvanically isolated), to start the ultrasonic cleaning |
| Temperature range | Operating +1...+40 °C; storage -20...+70 °C |
| Protection class | IP64 |
| Dimensions and weight | 115 × 136 × 90 mm (W × H × D), approx. 1 kg |
| Visual inspection | Monitoring window with integrated lighting unit |
TriOS FlowCell FC 48/10 USC is a bypass flow cell with integrated ultrasonic cleaning for TriOS sensors with an optical path length of up to 10 mm. It combines installation in a bypass line with direct cleaning of the measurement windows, and an integrated monitoring window with a lighting unit lets operators check the condition of the optical path at any time. The housing is made of POM (polyoxymethylene). Mikron Proses (Üsküdar, Istanbul), TriOS’s solution partner in Turkey, provides application consulting on sensor and flow cell selection, commissioning and calibration.
Application consulting · Commissioning · Calibration → Send us your requirement
Ultrasonic cleaning of the optical windows
Fouling on the measurement windows of an optical sensor can be prevented by ultrasound. The ultrasonic generator in the FC 48/10 USC runs on 12-24 VDC (power consumption up to 15 W). A galvanically isolated trigger input (5-24 VDC) starts the cleaning cycle from an external controller or system.
Hydraulic and mechanical data
The flow cell is designed for a maximum pressure of 1 bar at a flow of 2-4 L/min. The housing is made of POM, protection class is IP64, and the dimensions are 115 × 136 × 90 mm for a weight of approx. 1 kg. The operating temperature range is +1…+40 °C.
Where it fits
The FC 48/10 USC is intended for TriOS optical sensors with an optical path length of up to 10 mm. The LISA-254 SAC254 sensor, the NICO nitrate meter and the NICO plus UV photometer are each offered with optical path lengths of 10 mm or shorter. For all analyzers, see online analyzers.
Applications
- Bypass installation of TriOS optical sensors
- Prevention of fouling on optical windows with ultrasound
- Visual inspection of the optical path during operation
Datasheets and manuals
Documents were last compared with the manufacturer's source on 2026-09-16.
Other TriOS products
- TriOS EGC Water Analyzer Online Analyzers
- TriOS enviroFlu-HC Oil-in-Water and PAH Sensor Online Analyzers
- TriOS LISA-254 SAC254 Sensor Online Analyzers
- TriOS microFlu V2 Fluorometer Online Analyzers
- TriOS NICO Nitrate Meter Online Analyzers
- TriOS NICO plus UV Photometer Online Analyzers
- TriOS OPUS aero Spectral Sensor Online Analyzers
- TriOS OPUS Spectral Sensor Online Analyzers
- TriOS TriBox3 and TriBox mini Controllers Online Analyzers
- TriOS TW Series Water Sensors Online Analyzers
Send us your requirement for TriOS FlowCell FC 48/10 USC
Describe your application; we will help you identify the right model and configuration.