TriOS TW Series Water Sensors

TriOS TW series sensors measure pH, conductivity and temperature (TW pH/EC) and turbidity by nephelometry (TW Turb-40, TW Turb-W40) in drinking water monitoring.

Send us your requirement

TriOS TW Series Water Sensors — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Measured parameters (TW pH/EC)pH, electrical conductivity (EC), temperature
pH measuring range and accuracy0-14 pH, ± 0.06 pH accuracy
Conductivity measuring range and accuracy0-5000 µS/cm; ± 40 µS/cm at 1000 µS/cm and ± 200 µS/cm at 5000 µS/cm (DIN EN 27888:1993)
Temperature measurement and compensation0-65 °C, compensation with a Pt1000 temperature sensor
Response time (T90)15 s (rising), 20 s (falling)
Warm-up time< 5 minutes
Internal data storage8 GB internal data logger
Measuring principle (TW Turb)Nephelometry (90° scattering angle)
TW Turb-40860 nm LED light source, ISO 7027, 0-40 FNU, ± (5 % + 0.01) FNU accuracy
TW Turb-W40White light LED, EPA 180.1, 0-40 NTU, ± (5 % + 0.05) NTU accuracy

TriOS TW series water sensors measure pH, electrical conductivity, temperature and turbidity for drinking water monitoring. The series consists of the TW pH/EC combined sensor (0-14 pH, 0-5000 µS/cm, 0-65 °C, with an 8 GB data logger) and the TW Turb-40 and TW Turb-W40 turbidity sensors (0-40 FNU to ISO 7027 at 860 nm, and 0-40 NTU to EPA 180.1 with white light). Mikron Proses (Üsküdar, Istanbul), TriOS’s solution partner in Turkey, provides application consulting on sensor selection, commissioning and calibration.

Application consulting · Commissioning · Calibration → Send us your requirement

Sensors for water quality monitoring

The TriOS TW series covers key water quality parameters in drinking water monitoring. The manual specifies the TW pH/EC sensor for drinking water, and the TW Turb sensors for drinking water, groundwater and surface water. The family has the TW pH/EC combined sensor, which measures pH, electrical conductivity and temperature together, and the TW Turb sensors for nephelometric turbidity measurement.

Related pages: Online turbidimeter selection · Drinking water turbidity measurement

TW pH/EC combined sensor

TW pH/EC combines pH, conductivity and temperature in one housing. Conductivity is measured according to DIN EN 27888:1993, and an integrated Pt1000 sensor provides temperature compensation.

  • Measuring range and accuracy: ± 0.06 pH over 0-14 pH; ± 40 µS/cm at 1000 µS/cm and ± 200 µS/cm at 5000 µS/cm over 0-5000 µS/cm.
  • Response and warm-up: the T90 response time is 15 s in the rising direction and 20 s in the falling direction, and the device reaches stable measurement in less than 5 minutes.
  • Data storage: an 8 GB internal data logger stores measured values.

TW Turb turbidity sensors

The TW Turb sensors determine turbidity by nephelometry at a 90° scattering angle. Two models cover different standards:

  • TW Turb-40: an 860 nm LED light source and ISO 7027 measurement; 0-40 FNU range with ± (5 % + 0.01) FNU accuracy.
  • TW Turb-W40: a white light LED and US EPA 180.1 measurement; 0-40 NTU range with ± (5 % + 0.05) NTU accuracy.

For all analyzers, see online analyzers.

Applications

  • Monitoring of drinking water treatment plants and distribution networks
  • Groundwater monitoring
  • Surface water monitoring