Skip to main content
Üsküdar / İstanbul
TriOS

TriOS microFlu V2 Fluorometer

Compact immersion fluorometer for chlorophyll a, phycocyanin, CDOM, rhodamine, fluorescein and tryptophan, with RS-485 Modbus RTU and analog output.

Send us your requirement

TriOS microFlu V2 Fluorometer — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Measuring principleFluorescence; LED excitation wavelength and optical filters depend on the sensor version (parameter)
Light source and detectorLED + optical filter; photodiode + filter
Measured parameters (by version)Chlorophyll a, phycocyanin (cyanobacteria), CDOM, tryptophan, rhodamine, fluorescein
Accuracy± (5 % + detection limit)
Response time (T90)6 s (default)
Smallest measuring interval3 s (default)
Digital interfaceRS-485, Modbus RTU
Analog output4-20 mA (max. load 500 Ω); 0-5 V or 0-10 V (min. load 1 kΩ)
Power consumptionTypically max. 0.6 W (max. 1.1 W with the analog interface active); max. 70 mW in power-down mode
Power supply12-24 VDC (± 10 %)
Housing materialStainless steel (1.4571 / 1.4404) or titanium (3.7035)
Dimensions and weightApprox. 162 mm × 48 mm (L × Ø); stainless steel approx. 650 g, titanium approx. 510 g
Pressure rating30 bar with SubConn connector; 3 bar with fixed cable; 1 bar in a flow cell (2-4 L/min)
Protection classIP68, NEMA 6P
Operating temperatureSample and ambient +2...+40 °C
Flow velocity0.1-10 m/s
Maintenance and calibrationTypically ≤ 0.5 h/month; calibration interval 24 months

TriOS microFlu V2 is a compact submersible fluorometer for the measurement of chlorophyll a, phycocyanin in cyanobacteria, colored dissolved organic matter (CDOM) and fluorescent tracers. It is supplied in versions that differ in their LED excitation wavelength and optical filters, one version for each measured parameter. The housing measures only 48 mm in diameter and about 162 mm in length. Mikron Proses (Üsküdar, Istanbul), TriOS’s solution partner in Turkey, provides application consulting on sensor selection, commissioning and calibration.

Application consulting · Commissioning · Calibration → Send us your requirement

Parameters and power consumption

The microFlu V2 family is built as versions that are fitted at the factory for the target parameter:

  • Algae and biomass: chlorophyll a for monitoring surface waters, and phycocyanin for cyanobacteria.
  • Organic content: CDOM, and tryptophan for wastewater-related organic pollution.
  • Tracers: rhodamine and fluorescein for fluorescent tracer measurements.

Internal reference signals of the LEDs used for fluorescence excitation compensate ageing effects and temperature influences. Power consumption is typically 0.6 W at most, and 70 mW at most in power-down mode.

Interfaces and construction

The sensor has an RS-485 Modbus RTU digital interface and a 4-20 mA analog output (optionally 0-5 V or 0-10 V), so measured values can be read out digitally or as an analog signal. The housing is made of 1.4571 / 1.4404 stainless steel or of titanium (3.7035), the SubConn connector version is rated for 30 bar, and protection is IP68 and NEMA 6P. For the chlorophyll measuring principle, see the chlorophyll-a sensor guide; for other TriOS fluorometers, see the TriOS enviroFlu-HC oil-in-water sensor and online analyzers.

Applications

  • Monitoring of chlorophyll a and cyanobacteria (phycocyanin) in surface waters
  • Colored dissolved organic matter (CDOM) monitoring
  • Tracer measurement with rhodamine and fluorescein
  • Tryptophan and organic pollution monitoring in wastewater treatment
  • Monitoring of sea and river waters
  • Submersible installation and in-line process measurement in flow cells

Datasheets and manuals

Documents were last compared with the manufacturer's source on 2026-09-16.

Send us your requirement for TriOS microFlu V2 Fluorometer

Describe your application; we will help you identify the right model and configuration.

Call Quote