Nuvonic UVpro Air Disinfection Series: Duct, Cooler and Room UVC Modules
UVC modules for ventilation ducts, air coolers and evaporators, and open production areas, from duct modules (KM) and cooler modules (LBD, LKEB, LKV) to ventilated V units (0-800 m³/h) and open WDO/WDS irradiators. Turkish catalogue (PDF) available.
Overview
UVpro is Nuvonic's (Hanovia) compact UVC module family for duct, cooling unit and open-area air disinfection in industrial facilities. The air devices fall into four main groups: duct modules, cooler and evaporator modules, ventilated air treatment units and open wall or ceiling irradiators. Flange modules (FM), storage tank modules (FMT/FMDT) and monitoring and measuring devices complete the range. All have stainless steel housings, are CE/EMC compliant and have a 12,000-hour lamp replacement interval.
The developer of the UVpro series, Nuvonic (formerly Orca GmbH, renamed NUVONIC GmbH in 2023), has built the series since 2014. Mikron Proses provides the product range as a Turkish catalogue (PDF) (20 pages, MK-KAT-NUV-26-001 Rev 00).
UVpro Air Models at a Glance
| Group | Models | Power and capacity | Use |
|---|---|---|---|
| Duct modules | KM 40, KM 50 | KM 40: 42-82 W input (3 lamp options), 14-32 W UVC; KM 50: 100 W input, 34 W UVC | Supply and exhaust ventilation ducts |
| Cooler and evaporator modules | LBD 40, LKEB, LKV | LBD 40: 41 W, rotating reflector, IP68; LKEB: 62-82 W (2 lamps); LKV: 400 mA / 230 V | Biofilm prevention on cooling fins of air coolers and evaporators |
| Ventilated air treatment units | V-Lab, V50 / V50-E, V300, V500, V1000 | V-Lab 0-100 m³/h, 80 W; V50/V50-E 50 m³/h, 35 W; V300 250 m³/h, 92 W; V500 250/450 m³/h (2 steps), 174 W; V1000 250-800 m³/h (adjustable), 296 W | Closed air circulation in laboratories, clinics, tasting rooms, production and maturation rooms |
| Open wall / ceiling irradiators | WDO, WDS | 20 / 30 / 40 W options; WDO 270° irradiation angle; WDS 360° rotating visual shield | Unoccupied areas only |
| Flange modules | FM 40, FM 50 | FM 40: 21/31/41 W (mono) or 42/62/82 W (duo) input, 7/11/14 W or 14/22/28 W UVC; FM 50: 50 W (mono) / 100 W (duo) input, 17 / 34 W UVC; IP68, 0...+40 °C | Air ducts, storage tanks, pools and in-plant applications |
| Storage tank modules | FMMT 30/40, FMDT 30/40 | FMMT: 31/41 W input, 11/16 W UVC; FMDT: 62/82 W input, 22/32 W UVC; flange mounted; IP68 | Air and inner surface disinfection of liquid storage tanks |
KM: Supply and Exhaust Duct Modules
UVpro KM 40 and KM 50 are fitted into supply and exhaust ventilation ducts for first installation or retrofit. The number of devices required is calculated against the air flow with software support. KM 40 offers three lamp options (K(T)20-4, K(T)30-4, K(T)40-4) with 42-82 W input and 14-32 W UVC output; KM 50 uses a single lamp type (K(T)50-4) with 100 W input and 34 W UVC output.
LBD / LKEB / LKV: Cooler and Evaporator Modules
These three modules are intended to prevent biofilm formation on the cooling fins of industrial air coolers and evaporators. LBD 40 (rotating reflector, IP68, -10...+20 °C) is mounted on the ceiling or wall, or directly inside an air cooler, and suits wet and foam cleaning. LKEB is offered as a quick installation kit for air coolers (LKEB 30/40, 62-82 W, IP68). LKV is mounted at the evaporator inlet, irradiates the cooling fins evenly, lets condensate flow unobstructed and increases cooling capacity (400 mA, IP68).
V Series: Ventilated Air Treatment Units
The V series scales with room volume as stand-alone ventilated units: V-Lab (0-100 m³/h, 80 W, wall mounted, low noise level of 1-31 dB for laboratories, clinics and tasting rooms), V50/V50-E (50 m³/h, 35 W, small laboratories and practices), V300 (250 m³/h, 92 W, production and maturation rooms), V500 (250/450 m³/h in two steps, 174 W) and V1000 (250-800 m³/h adjustable, 296 W, the highest capacity model, chain-hung mounting).
WDO / WDS: Open Wall and Ceiling Irradiators
UVpro WDO and WDS are open-type UVC irradiators used only in unoccupied areas; installation with a presence sensor or door switch is recommended. WDO irradiates at 270° and suits ceiling, wall or suspended mounting, with normal (N) or thermo (K) lamp options in 20/30/40 W steps. WDS has a 360° rotating visual shield reflector that hides the irradiation during working hours; outside working hours (for example at night) the reflector is turned so the whole room and its surfaces can be disinfected. Aluminium or PTFE reflector options (for humid areas) are available, with 24 V DC (WDS 24V) or 220-240 V AC (WDS) supply.
FM and FMT / FMDT: Flange and Storage Tank Modules
FM flange modules come in mono (single tube) and duo (double tube) versions for air ducts, storage tanks, pools and in-plant applications, either at first installation or retrofit; they are mounted from the outside and are an alternative to the KM module in ducts that are hard to reach. FM 40 offers three tube options with 21/31/41 W (mono) or 42/62/82 W (duo) input; FM 50 offers 50 W (mono) or 100 W (duo). Protection class is IP68, operating temperature 0...+40 °C, and the body is stainless steel, with an optional V4A 1.4404 (316L) steel for FM 40.
FMT / FMDT UV-C disinfectors are designed for the air and inner surfaces of storage tanks. The tubes are flange-mounted to the tank and extend inside, disinfecting the air drawn in and the inner walls. The supplied monitoring unit gives an alarm through a potential-free contact for failure or tube breakage, and PTFE-coated tubes provide breakage protection for HACCP and IFS requirements. Supply is 220-240 V AC, 50-60 Hz.
Monitoring and Measuring Devices
- UVC-Line module (DM 2081): monitors current, operating hours and ignition count of 8 tube circuits in UV-C installations; RS 485 bus, potential-free signal contact and optional UV-C power sensor input. Measuring range 0...1,200 mA AC, 24 V DC supply, IP20.
- CU-1: a compact current monitoring module that alarms when operating current falls below a threshold; the threshold is factory-set in the 50...2,000 mA range; DIN rail mounted, IP20.
- UVC Safe: measures biologically weighted UV-C irradiance around 254 nm in the workplace based on Directive 2006/25/EC and determines the maximum permitted exposure time for skin and eyes (1 minute to 24 hours); connects to an Android device via mini USB.
- UVC Lampchecker: measures UV-C tube output, shows performance as a percentage and shows whether the tube needs replacing; for low-pressure UV-C lamp measurement only.
Common Specifications
| Parameter | Value |
|---|---|
| Housing material | Stainless steel WN 1.4301 / WN 1.4305 (PTFE or aluminium reflector in some models) |
| Lamp replacement interval | 12,000 hours (at 75±5% output performance) |
| Electronics life | More than 10 years (6 years for the LKV module) |
| Protection class | IP51 to IP68 depending on model; EMC and CE compliant |
How Mikron Proses Helps
Which UVpro air module (duct, cooler or open-area type) suits your facility depends on air volume, duct size and whether the area is accessible to people. Mikron Proses supplies Nuvonic UVpro air disinfection systems and original UVC tubes in Turkey, with room and duct project sizing, supply, installation and commissioning. Describe your need and we will select the model together. For the other UV product groups, see UV systems and the Nuvonic brand page; for the surface series, see UVpro surface disinfection.
Documents
- Turkish catalogue (PDF) (MK-KAT-NUV-26-001 Rev 00, 20 pages)
- UVpro KM 40 datasheet · KM 50 · LBD 40 · LKEB · LKV
- V-Lab · V50 · V50 E · V300 · V500 · V1000
- WDO · WDS · WDS 24V · FM 40 · FM 50 · FMT
- UVC-Line (DM 2081) · CU-1 · UVC Safe · UVC Lampchecker
Datasheets are the manufacturer's documents; the catalogue is in Turkish.
Frequently Asked Questions
Technical answers from Mikron Proses.
Where are the UVpro KM, LBD/LKEB/LKV, V series and WDO/WDS units used?
UVpro KM is used in supply and exhaust ventilation ducts; LBD 40 (41 W, IP68), LKEB (62-82 W) and LKV (400 mA/230 V) on cooler and evaporator surfaces; the ventilated V series (0-800 m³/h) for closed air circulation inside rooms; and the WDO/WDS (20/30/40 W) open wall-ceiling irradiators for direct irradiation in unoccupied areas only.
What are the air flow and power ratings of the ventilated UVpro V series?
The series includes V-Lab (0-100 m³/h, 80 W), V50/V50-E (50 m³/h, 35 W), V300 (250 m³/h, 92 W), V500 (250/450 m³/h in two steps, 174 W) and V1000 (250-800 m³/h, 296 W).
What are the power options of the UVpro KM duct modules?
KM 40 gives 14-32 W UVC output at 42-82 W input depending on the tube type; KM 50 gives 34 W UVC output at 100 W input.
What are the housing material and lamp life of the UVpro air series?
Housings are made of WN 1.4301 / 1.4305 stainless steel; the UVC tubes have an operating life of 12,000 hours (at 75±5% output performance).
Is it safe to be in a room with open UVC irradiators?
WDO and WDS open irradiators are used only in unoccupied areas, and installation with a presence sensor or door switch is recommended. The WDS has a rotating visual shield so that irradiation is hidden during working hours and used when the room is empty. UVC exposure limits for the workplace can be assessed with the UVC Safe measuring device, which is based on Directive 2006/25/EC.
Who supplies Nuvonic UVpro air disinfection units in Turkey?
Mikron Proses (Üsküdar, Istanbul) supplies Nuvonic UVpro air disinfection systems and original UVC tubes in Turkey, with room and duct project sizing, supply, installation and commissioning. A Turkish catalogue (PDF) is available.
Planning a project? Send us your flow rate, feed water source and target water quality to [email protected] — our engineers will reply with a technical proposal.