Hefer CLO-3000C Online Chlorine Dioxide Analyzer
Online chlorine dioxide (ClO2) measurement in drinking water, food and cooling water lines with the Hefer CLO-3000C analyzer: potentiostatic PME sensor, 0.01-20 ppm, two control relays and a 4-20 mA output.
Send us your requirementHefer CLO-3000C Online Chlorine Dioxide Analyzer — describe your application and we will help you identify the right model and configuration together.
Technical specifications

| CLO-3000C controller | 0.01-20 ppm ClO2; resolution 0.01 / 0.001 ppm; accuracy ±2% of the reading; 2 × SPDT control relays (On/Off, PWM, PFM) + 1 × SPDT alarm relay, 5 A dry contacts; isolated 4-20 mA output |
|---|---|
| PME chlorine dioxide sensor | Potentiostatic measuring electrode with two platinum electrodes (epoxy body, 12 mm), a double-junction ceramic reference and a Pt100 temperature sensor; automatic temperature compensation |
| Enclosure | IP-65 wall-mount enclosure with a clear door and two locks (350 × 350 × 180 mm); keyboard lock option |
| Calibration | 3-way sample / zero valve; one-point field calibration takes no longer than 2 minutes |
The Hefer CLO-3000C is an online analyzer that measures chlorine dioxide (ClO₂) continuously in the range of 0.01-20 ppm with a potentiostatic PME sensor, ±2% accuracy of the reading and 0.01 / 0.001 ppm resolution. It has two SPDT control relays, one alarm relay, an isolated 4-20 mA output and an IP-65 wall-mount enclosure with a clear door. As the Hefer distributor in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies, commissions and calibrates Hefer analyzers.
The CLO-3000C is a potentiostatic analysis system that monitors the chlorine dioxide (ClO₂) concentration continuously in water conditioning and disinfection lines.
Main features
- PME chlorine dioxide sensor: a potentiostatic measuring electrode with automatic temperature compensation.
- CLO-3000C controller: measures in the 0.01-20 ppm range. It has two SPDT relays (On/Off, PWM or PFM) to drive dosing pumps or a chlorine dioxide generator, one alarm relay and an isolated 4-20 mA output.
- Calibration: a 3-way valve supplies both the sample water and the zero sample; a one-point calibration can be done in the field in no longer than 2 minutes. The controller has an optional keyboard lock.
Related pages
Applications
- Continuous chlorine dioxide disinfection monitoring in network and well water
- Chlorine dioxide control of CIP and rinse water in food and beverage lines
- Legionella prevention and biocide dosing automation in cooling towers
Datasheets and manuals
- Hefer CLO-3000C Chlorine Dioxide Analyzer Datasheet Datasheet · PDF
- Hefer 2030 Series Transmitter Manual User manual · PDF
Documents were last compared with the manufacturer's source on 2026-08-23.
Other Hefer products
- Hefer 2030 Series Industrial Transmitters Online Measurement and Automation Systems
- Hefer CL Series Online Chlorine Analyzers and PME Sensor Systems Online Measurement and Automation Systems
- Hefer O3-3000C Online Ozone Analyzer and PME Sensor Systems Online Measurement and Automation Systems
- Hefer TU Series Online Turbidity Sensors Online Measurement and Automation Systems
- Hefer WHA Series Online Water Hardness Analyzer (WHA-3000-C / WHA-2000) Online Measurement and Automation Systems
Send us your requirement for Hefer CLO-3000C Online Chlorine Dioxide Analyzer
Describe your application; we will help you identify the right model and configuration.