Walchem WEL / WDS Series pH/ORP Sensors and Preamplifiers

Walchem differential pH/ORP sensors: the modular-cartridge WEL series, the WDS series with replaceable salt bridge, and preamplifiers that connect standard electrodes to Walchem controllers.

Send us your requirement

Walchem WEL / WDS Series pH/ORP Sensors and Preamplifiers — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Walchem WEL modular cartridge pH/ORP sensors with gray housings next to a small electrode cartridge
WEL series: principleDifferential pH/ORP electrode with a titanium solution ground rod integral to the housing; resistant to stray voltages and currents and to ground loops; the preamplifier is powered by the controller, so there is no battery
WEL series: cartridgespH: flat surface (PHF), bulb (PHB), HF resistant (PHH), flat surface for samples of 10-100 µS/cm (PHLI); ORP: flat surface (MVF), rod style (MVR); cartridges are changed in minutes without tools
WEL series: mounting and materials1 inch NPTM submersion, 3/4 inch NPTF inline tee, 1 1/4 inch BSPT metric inline or 1 1/4 inch NPT adapter; CPVC housing, HDPE reference junction, FKM o-rings, titanium ground rod, glass (pH) or platinum (ORP) electrode; operating pressure 6.9 bar
WEL series: range0-14 pH (0-12 without sodium ion error); ±1999 mV (ORP)
WDS series: principleTwo-electrode differential measurement (process and reference) against a third metal electrode; the reference is a glass electrode embedded in pH 7 buffer behind a porous, replaceable salt bridge
WDS series: performance0-14 pH and -2000 to 2000 mV (ORP); sensitivity 0.001 pH and 0.1 mV; stability 0.03 pH per day and 2 mV per day (non-cumulative); temperature -5 to 95 °C; pressure limit 0.7 MPa at 65 °C
WDS series: materials and approvalCPVC, ceramic, glass, EPDM, platinum (ORP only) and titanium palladium alloy; models with a Walchem preamplifier (WDS-**W) comply with CE EMC EN 61326
Preamplifier functionAllows any standard non-amplified pH/ORP/ISE electrode to be used with Walchem controllers; the amplified signal can be extended up to 305 m with 22 AWG cable; no temperature simulation resistor is needed with Walchem controllers
Preamplifier typesExternal type in a NEMA 4X wall-mount enclosure for long cable runs (electrode connected by a short coax cable); internal type mounted in the controller enclosure for total cable runs under 6 m; terminal block or BNC input
High pressure / high temperature electrodes102029 (pH) and 102963 (ORP): up to 34.5 bar at 25 °C and -5 to 135 °C at 13.8 bar; double-junction reference (Na2SO4 + KCl, Ag/AgCl); 3.05 m cable with BNC connector; 58.7 ± 0.3 mV per pH unit

Walchem’s pH/ORP line is built around differential measurement: the WEL series with replaceable measuring cartridges, the WDS series with a replaceable salt bridge, preamplifiers that connect standard electrodes to Walchem controllers, and special electrodes for high temperature and pressure. The differential technique makes the signal resistant to stray voltages and currents and to ground loop problems. As the Walchem distributor in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies WEL and WDS electrodes, replacement cartridges and preamplifiers and provides application consulting for electrode selection, controller connection, commissioning and calibration support.

Tell us the solution, temperature and controller and we will select the electrode → Send us your requirement

Comparison

Product groupMeasuring principle and cartridge / referenceLimitsTypical use
WEL series (modular cartridge)Differential, titanium ground rod in the housing; cartridges PHF, PHB, PHH, PHLI (pH) and MVF, MVR (ORP)CPVC housing, 6.9 barIndustrial pH/ORP measurement, inline or submersion
WDS series (full differential)Glass reference in pH 7 buffer with replaceable porous salt bridge, third metal ground electrode; 0.001 pH / 0.1 mV sensitivity-5 to 95 °C, 0.7 MPa at 65 °CIndustrial and municipal applications
102029 (pH) / 102963 (ORP)Double-junction Na₂SO₄ + KCl / Ag/AgCl reference, 58.7 ± 0.3 mV per pH34.5 bar at 25 °C; -5 to 135 °C at 13.8 barHigh temperature and high pressure lines
PreamplifierConverts the high-impedance signal of a standard pH/ORP/ISE electrode to a differential signalUp to 305 m (22 AWG) after amplificationStandard BNC electrodes on Walchem controllers

WEL series: modular cartridge electrodes

The WEL has a rugged CPVC housing that contains the electronics. The pH and ORP cartridges are connected or replaced in minutes without tools, with a threaded interlock connection and a double FKM o-ring seal. The preamplifier (or an optional 4-20 mA transmitter) and the temperature compensation element stay in the housing when a cartridge is replaced, which lowers operating cost. The titanium solution ground rod in the housing enables the differential technique, which extends electrode life. The preamplifier is powered by the controller, so the signal is always amplified and there is no battery. Cartridge options are flat surface (PHF), bulb (PHB) and HF resistant (PHH) for pH, flat surface (MVF) and rod style (MVR) for ORP, and a flat pH cartridge (PHLI) for samples between 10 and 100 µS/cm. The same housing and cartridge can be used for submersion and inline mounting, which reduces spare parts stock.

WDS series: differential sensors with a salt bridge

The WDS series uses two electrodes, one for the process measurement and one for the reference measurement, each measured against a third metal electrode. The reference is a glass electrode embedded in pH 7 buffer behind a porous, replaceable salt bridge; if the bridge clogs or the solution is contaminated it is easily replaced, and the glass reference is not prone to chemical attack in the way a silver/silver chloride reference can be. The range is 0-14 pH and -2000 to 2000 mV (ORP), with a stability of 0.03 pH and 2 mV per day.

Preamplifiers and high-temperature electrodes

If you already have a standard, non-amplified pH/ORP/ISE electrode, a Walchem preamplifier makes it usable with Walchem controllers. For total cable runs under 6 m the internal preamplifier is mounted in the controller enclosure; for longer runs the external NEMA 4X wall-mount enclosure is used, and the amplified signal is carried up to 305 m. For conditions that standard CPVC electrodes cannot take, the 102029 (pH) and 102963 (ORP) electrodes are available.

The electrodes connect to the W100P panel-mount controller, the Intuition-6 and Intuition-9 controllers; the WEL and WDS series are the sensors recommended in the Intuition brochures. For background see the pH electrode selection guide and the Walchem brand page.

Applications

  • Industrial and municipal pH and ORP measurement with differential sensors
  • Aggressive solutions that contain hydrofluoric acid (HF resistant PHH cartridge)
  • High temperature and high pressure process lines (102029 / 102963 electrodes)