Walchem WEL / WDS Series pH/ORP Sensors and Preamplifiers
Walchem differential pH/ORP sensors: the modular-cartridge WEL series, the WDS series with replaceable salt bridge, and preamplifiers that connect standard electrodes to Walchem controllers.
Send us your requirementWalchem WEL / WDS Series pH/ORP Sensors and Preamplifiers — describe your application and we will help you identify the right model and configuration together.
Technical specifications

| WEL series: principle | Differential pH/ORP electrode with a titanium solution ground rod integral to the housing; resistant to stray voltages and currents and to ground loops; the preamplifier is powered by the controller, so there is no battery |
|---|---|
| WEL series: cartridges | pH: flat surface (PHF), bulb (PHB), HF resistant (PHH), flat surface for samples of 10-100 µS/cm (PHLI); ORP: flat surface (MVF), rod style (MVR); cartridges are changed in minutes without tools |
| WEL series: mounting and materials | 1 inch NPTM submersion, 3/4 inch NPTF inline tee, 1 1/4 inch BSPT metric inline or 1 1/4 inch NPT adapter; CPVC housing, HDPE reference junction, FKM o-rings, titanium ground rod, glass (pH) or platinum (ORP) electrode; operating pressure 6.9 bar |
| WEL series: range | 0-14 pH (0-12 without sodium ion error); ±1999 mV (ORP) |
| WDS series: principle | Two-electrode differential measurement (process and reference) against a third metal electrode; the reference is a glass electrode embedded in pH 7 buffer behind a porous, replaceable salt bridge |
| WDS series: performance | 0-14 pH and -2000 to 2000 mV (ORP); sensitivity 0.001 pH and 0.1 mV; stability 0.03 pH per day and 2 mV per day (non-cumulative); temperature -5 to 95 °C; pressure limit 0.7 MPa at 65 °C |
| WDS series: materials and approval | CPVC, ceramic, glass, EPDM, platinum (ORP only) and titanium palladium alloy; models with a Walchem preamplifier (WDS-**W) comply with CE EMC EN 61326 |
| Preamplifier function | Allows any standard non-amplified pH/ORP/ISE electrode to be used with Walchem controllers; the amplified signal can be extended up to 305 m with 22 AWG cable; no temperature simulation resistor is needed with Walchem controllers |
| Preamplifier types | External type in a NEMA 4X wall-mount enclosure for long cable runs (electrode connected by a short coax cable); internal type mounted in the controller enclosure for total cable runs under 6 m; terminal block or BNC input |
| High pressure / high temperature electrodes | 102029 (pH) and 102963 (ORP): up to 34.5 bar at 25 °C and -5 to 135 °C at 13.8 bar; double-junction reference (Na2SO4 + KCl, Ag/AgCl); 3.05 m cable with BNC connector; 58.7 ± 0.3 mV per pH unit |
Walchem’s pH/ORP line is built around differential measurement: the WEL series with replaceable measuring cartridges, the WDS series with a replaceable salt bridge, preamplifiers that connect standard electrodes to Walchem controllers, and special electrodes for high temperature and pressure. The differential technique makes the signal resistant to stray voltages and currents and to ground loop problems. As the Walchem distributor in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies WEL and WDS electrodes, replacement cartridges and preamplifiers and provides application consulting for electrode selection, controller connection, commissioning and calibration support.
Tell us the solution, temperature and controller and we will select the electrode → Send us your requirement
Comparison
| Product group | Measuring principle and cartridge / reference | Limits | Typical use |
|---|---|---|---|
| WEL series (modular cartridge) | Differential, titanium ground rod in the housing; cartridges PHF, PHB, PHH, PHLI (pH) and MVF, MVR (ORP) | CPVC housing, 6.9 bar | Industrial pH/ORP measurement, inline or submersion |
| WDS series (full differential) | Glass reference in pH 7 buffer with replaceable porous salt bridge, third metal ground electrode; 0.001 pH / 0.1 mV sensitivity | -5 to 95 °C, 0.7 MPa at 65 °C | Industrial and municipal applications |
| 102029 (pH) / 102963 (ORP) | Double-junction Na₂SO₄ + KCl / Ag/AgCl reference, 58.7 ± 0.3 mV per pH | 34.5 bar at 25 °C; -5 to 135 °C at 13.8 bar | High temperature and high pressure lines |
| Preamplifier | Converts the high-impedance signal of a standard pH/ORP/ISE electrode to a differential signal | Up to 305 m (22 AWG) after amplification | Standard BNC electrodes on Walchem controllers |
WEL series: modular cartridge electrodes
The WEL has a rugged CPVC housing that contains the electronics. The pH and ORP cartridges are connected or replaced in minutes without tools, with a threaded interlock connection and a double FKM o-ring seal. The preamplifier (or an optional 4-20 mA transmitter) and the temperature compensation element stay in the housing when a cartridge is replaced, which lowers operating cost. The titanium solution ground rod in the housing enables the differential technique, which extends electrode life. The preamplifier is powered by the controller, so the signal is always amplified and there is no battery. Cartridge options are flat surface (PHF), bulb (PHB) and HF resistant (PHH) for pH, flat surface (MVF) and rod style (MVR) for ORP, and a flat pH cartridge (PHLI) for samples between 10 and 100 µS/cm. The same housing and cartridge can be used for submersion and inline mounting, which reduces spare parts stock.
WDS series: differential sensors with a salt bridge
The WDS series uses two electrodes, one for the process measurement and one for the reference measurement, each measured against a third metal electrode. The reference is a glass electrode embedded in pH 7 buffer behind a porous, replaceable salt bridge; if the bridge clogs or the solution is contaminated it is easily replaced, and the glass reference is not prone to chemical attack in the way a silver/silver chloride reference can be. The range is 0-14 pH and -2000 to 2000 mV (ORP), with a stability of 0.03 pH and 2 mV per day.
Preamplifiers and high-temperature electrodes
If you already have a standard, non-amplified pH/ORP/ISE electrode, a Walchem preamplifier makes it usable with Walchem controllers. For total cable runs under 6 m the internal preamplifier is mounted in the controller enclosure; for longer runs the external NEMA 4X wall-mount enclosure is used, and the amplified signal is carried up to 305 m. For conditions that standard CPVC electrodes cannot take, the 102029 (pH) and 102963 (ORP) electrodes are available.
Related pages
The electrodes connect to the W100P panel-mount controller, the Intuition-6 and Intuition-9 controllers; the WEL and WDS series are the sensors recommended in the Intuition brochures. For background see the pH electrode selection guide and the Walchem brand page.
Applications
- Industrial and municipal pH and ORP measurement with differential sensors
- Aggressive solutions that contain hydrofluoric acid (HF resistant PHH cartridge)
- High temperature and high pressure process lines (102029 / 102963 electrodes)
Datasheets and manuals
- Walchem pH/ORP Sensor Preamplifiers (WEL Series) Datasheet Datasheet · PDF
- WEL Series pH/ORP Electrodes Datasheet Datasheet · PDF
- WDS Series Differential pH/ORP Sensor Datasheet Datasheet · PDF
Documents were last compared with the manufacturer's source on 2026-10-30.
Other Walchem products
- Walchem Intuition-6 Series Water Treatment Controller Online Measurement and Automation Systems
- Walchem Intuition-9 Series Water Treatment Controller Online Measurement and Automation Systems
- Walchem P100 Series Panel-Mount Controller (WCNP / WPHNP / WPHBP) Online Measurement and Automation Systems
- Walchem W100W Cooling Tower and Boiler Controller Online Measurement and Automation Systems
- Walchem W100P Series Panel-Mount Controller (WCNP / WPHNP / WPHBP) Online Measurement and Automation Systems
- Walchem W100W Series Wall-Mount Controller Online Measurement and Automation Systems
- Walchem W600 Series Controller Online Measurement and Automation Systems
- Walchem W900 Series Controller Online Measurement and Automation Systems
- Walchem Amperometric Disinfection Sensors (Chlorine Dioxide, Peracetic Acid, Hydrogen Peroxide, Ozone, Chlorite) Online Measurement and Automation Systems
- Walchem Conductivity Sensors (Contacting and Electrodeless / Toroidal) Online Measurement and Automation Systems
- Walchem WebAlert Remote Monitoring and Datalogging Controller Online Measurement and Automation Systems
- Walchem WIND (WebMaster Industrial) Series Water Treatment Controller Online Measurement and Automation Systems
Send us your requirement for Walchem WEL / WDS Series pH/ORP Sensors and Preamplifiers
Describe your application; we will help you identify the right model and configuration.