Technical specifications

Nuvonic ProLine UV reactor: a stainless steel cylindrical chamber with flanged connections, shown as a series image
ProLine PQ AF: maximum power200-750 W (3 models, 0008 to 0090); single low pressure lamp, low energy amalgam range for small communities, USEPA validated
ProLine PQ AL: maximum power2.4-7.2 kW (2 models, PQ AL 100 and PQ AL 300); multi-lamp low pressure (4 and 12 lamps), USEPA validated, stepless lamp power adjustment from flow and UVT meter inputs
ProLine PQ EO: maximum power4.5-6.8 kW (5 models, PQ EO 4 to PQ EO 12); single medium pressure lamp, USEPA validated, energy optimised
ProLine PQ IL and PQ IL DVGW: maximum powerPQ IL: 5.6-52 kW (6 models, USEPA validated); PQ IL DVGW: 1.8-52 kW (7 models, DVGW certified); compact medium pressure
ProLine PQ WW AL: maximum power2.4-7.2 kW (2 models, PQ WW AL 100 and PQ WW AL 300); multi-lamp low pressure, wastewater reuse, NWRI validation stated for PQ WW AL 100 only
ProLine PQ WW IL: maximum power5.6-117 kW (9 models, PQ WW IL 250 to 18000); compact medium pressure, NWRI validated for wastewater reuse
Chamber materialStainless steel 316L / 1.4404
UV sensorCalibrated or dry DVGW compliant UV sensor; UVGuard™ window on PQ AF and PQ EO
CertificationsCE marked; PQ AF, PQ AL, PQ EO and PQ IL USEPA (UVDGM); PQ IL DVGW DVGW certified; PQ IL also NSF 61; PQ WW AL and PQ WW IL NWRI validated

Nuvonic ProLine is a range of third-party validated or certified UV systems in two application groups: municipal drinking water disinfection (PQ AF, PQ AL, PQ EO, PQ IL, PQ IL DVGW) and wastewater reuse (PQ WW AL, PQ WW IL). For drinking water, UV is used worldwide as a Cryptosporidium barrier, because even at low doses it protects against chlorine resistant pathogens such as Cryptosporidium and Giardia. Mikron Proses (Üsküdar, Istanbul) offers the range with model selection, supply and commissioning.

ProLine WW IL, the basic wastewater model without third-party validation, has its own page: Nuvonic ProLine WW IL. Every variant on this page has a 316L stainless steel chamber, flanged process connections and an automatic wiper.

Five drinking water variants, five levels of validation and capacity

PQ AF is a low energy, single-lamp amalgam range for small communities (3 models, 200-750 W). It has a dry DVGW approved UV sensor and an RS 485 Modbus interface, and its dose equations and sizing are validated to the USEPA UV Disinfection Guidance Manual.

PQ AL gives higher capacity for small to mid-sized communities with a multi-lamp low pressure design (4 lamps in PQ AL 100, 12 lamps in PQ AL 300). Stepless lamp power adjustment from flow and UVT meter inputs optimises energy use.

PQ EO gives high treatment capacity with a single medium pressure lamp (5 models, PQ EO 4 to 12, 4.5-6.8 kW). The UV sensor has a UVGuard™ window that allows a safe audit while the system is running, and UVShield™ power cut-out and water leak detection are optional.

PQ IL and PQ IL DVGW are compact medium pressure designs for small to mid-sized communities where space is tight. PQ IL is USEPA validated and lists NSF 61 among its approvals (6 models, 5.6-52 kW); PQ IL DVGW is DVGW certified (7 models, 1.8-52 kW). Both have a dry DVGW compliant UV sensor; on PQ IL there is one per lamp.

NWRI validation for wastewater reuse

PQ WW AL (2 models, PQ WW AL 100 and 300, 2.4-7.2 kW) and PQ WW IL (9 models, PQ WW IL 250 to 18000, 5.6-117 kW) serve tertiary disinfection after sand filters or membrane filters. The PQ WW IL datasheet states third-party validation to the National Water Research Institute (NWRI) standard across a wide range of dose, flow and UVT parameters. For PQ WW AL, the datasheet states NWRI validation for the PQ WW AL 100 model only. An optional Ultrawipe (chemically enhanced wiper) for PQ WW IL keeps the quartz sleeves clean in water with high fouling potential. Compared with chlorination, UV avoids generating potentially harmful by-products and supports the production of water for irrigation, aquifer recharge or direct reuse.

Power by variant (datasheets)

VariantNumber of modelsMaximum powerLamp
PQ AF3200-750 WLow pressure amalgam, 1 lamp
PQ AL22.4-7.2 kWLow pressure, 4 or 12 lamps
PQ EO54.5-6.8 kWMedium pressure, 1 lamp
PQ IL65.6-52 kWMedium pressure
PQ IL DVGW71.8-52 kWMedium pressure
PQ WW AL22.4-7.2 kWLow pressure, 4 or 12 lamps
PQ WW IL95.6-117 kWMedium pressure

The datasheets give lamp power and number of models, not flow capacity. Flow selection depends on UVT and the disinfection target, and is done per project.

Which variant (which validation standard, which capacity) suits your process depends on the plant flow, the UV transmittance and the discharge or reuse standard. Describe your requirement and we can select the model together.

Applications

  • Low energy Cryptosporidium and Giardia barrier at small to mid-sized municipal drinking water plants (PQ AF, PQ AL)
  • Energy optimised drinking water disinfection with a single lamp (PQ EO)
  • Compact USEPA or DVGW validated drinking water disinfection where space is tight (PQ IL, PQ IL DVGW)
  • NWRI validated tertiary disinfection for wastewater reuse such as irrigation and aquifer recharge (PQ WW AL, PQ WW IL)