Nuvonic PureLine PQ AF UV chamber: a long horizontal stainless steel tube with a UV sensor cable at the top
Maximum power range125-750 W (PureLine PQ AF 0005 to PQ AF 0090)
Lamp type and lifeLow pressure amalgam, one lamp per chamber, 12,000 hours expected lamp life
Chamber materialStainless steel 316L / 1.4404
Minimum T1060%
Working fluid temperature5°C to 40°C
Operating pressure10 bar (positive pressure only)
Maximum CIP temperature130°C (PQ AF 0005 to 0016); 95°C with the cabinet electrically isolated (PQ AF 0030 to 0090)
SealsEPDM, ADI free, EC 1935/2004 and FDA 21 CFR 177.2600 approved
Control and communicationFlow and UVT meter inputs (4-20 mA); UV dose and UV intensity outputs (4-20 mA); RS 485 Modbus
CertificationsCE marked

Nuvonic (formerly Hanovia) PureLine PQ AF is a UV disinfection system for product and process waters in the food and beverage industry, with third-party bioassayed performance. The series runs from PQ AF 0005 to PQ AF 0090 (125-750 W), uses low pressure amalgam lamps with about 12,000 hours of expected life, a 316L (1.4404) stainless steel chamber and EPDM seals approved to FDA 21 CFR 177.2600 and EC 1935/2004. The maximum CIP temperature is 95°C to 130°C depending on the model (source: Nuvonic PureLine PQ AF datasheet). Mikron Proses (Üsküdar, Istanbul), the Nuvonic distributor in Turkey, supplies the system with installation and commissioning.

PureLine PQ AF is built for UV treatment of food and beverage waters whose dose equations and sizing have been independently derived and tested in accordance with the USEPA UV Disinfection Guidance Manual. A certified dry UV sensor measures the germicidal output, and a real-time RED dose reading with a low dose warning makes the performance easy to monitor and log. When flow and UV transmittance (UVT) meters are connected, the dose reading is based on the actual process conditions.

Hygienic design

The wetted parts are made of FDA-approved materials. The chamber is 316L (1.4404) stainless steel, and the ADI-free EPDM seals are approved to EC 1935/2004 and FDA 21 CFR 177.2600. An optional chamber with tri-clamp connections and an internal finish below 0.8 µm gives a sanitary design, suited to CIP procedures (95°C to 130°C hot water, depending on the model).

PureLine PQ AF models

ModelMaximum power (W)Minimum T10 (%)
PQ AF 000512560
PQ AF 000820060
PQ AF 001635060
PQ AF 003035060
PQ AF 009075060

The datasheet gives lamp power and minimum T10 per model, not flow capacity. Flow selection depends on UVT and the disinfection target, and is done per project.

Where it is used in the process

Bottled water lines are a typical case: the unit protects source and process water, limits bio-fouling in pre-treatment equipment and RO filters before the membrane, helps prevent contamination during CIP, and acts as a final protection step before bottling. The compact design allows installation on skids or retrofitting to an existing process.

Applications

  • Source and process water disinfection in bottled water lines
  • Limiting bio-fouling of RO pre-treatment equipment and filters
  • Preventing contamination in the CIP (cleaning in place) system
  • Final protection step before bottling