PureLine Series Food & Beverage UV Systems
Nuvonic PureLine variants for food and beverage process water: basic disinfection, chlorine and chlorine dioxide removal, ozone removal, third-party bioassayed variants and the compact PureLine ECO.
Send us your requirementPureLine Series Food & Beverage UV Systems — describe your application and we will help you identify the right model and configuration together.
Technical specifications

| PureLine D AF / D EO H / D PH power range | D AF: 115-600 W (6 models, D AF 0003 to 0090, low pressure, standard or hygienic options); D EO H: 4.5-6.8 kW (3 models, medium pressure, hygienic tri-clamp); D PH: 1.6-33 kW (D PH 0070 to 0950, medium pressure, standard flanged) |
|---|---|
| PureLine DC PH / DCD PH power range | DC PH: 1.6-25.2 kW (free chlorine removal); DCD PH: 4.2-25.2 kW (5 models, chlorine dioxide removal); both medium pressure, UL listed (E149108) |
| PureLine DO AF / DO PH power range | DO AF: 345-700 W (3 models, low pressure); DO PH: 1.6-25.2 kW (9 models, medium pressure); residual ozone removal |
| PureLine PQ AL / PQ EO / PQ EO H+ / PQ IL power range | PQ AL: 2.4-7.2 kW (2 models, multi-lamp low pressure); PQ EO / EO H+: 4.5-9 kW (5 + 1 models, single medium pressure lamp, H+ hygienic); PQ IL: 5.6-52 kW (6 models, multi-lamp medium pressure); all third-party bioassayed |
| PureLine ECO flow and power range | 4.1-385 m³/h, 90-2440 W (12 models, ECO 4 to ECO 380); 7-inch touchscreen controller, compact design |
| Chamber material | 316L / 1.4404 stainless steel |
| Lamp life | Low pressure: D AF, DO AF and ECO 12,000 hours; PQ AL 9,000 hours. Medium pressure: D EO H, PQ EO and PQ EO H+ 9,000 hours; PQ IL 12,000 hours; D PH, DC PH, DCD PH and DO PH 8,000 hours (4,000 hours for D PH 0240 and 0300, DC PH 250 and 300, DCD PH 40 and DO PH 0119) |
| Seals | EPDM; FDA 21 CFR 177.2600 approved; ADI free and EC 1935/2004 stated for all variants except ECO |
| Approvals | CE marked; D PH, DC PH, DCD PH and DO PH UL listed (E149108); ECO UL; PQ IL third-party bioassayed and tested in accordance with the USEPA UV Disinfection Guidance Manual |
Nuvonic PureLine is a family of UV systems for food and beverage product and process water. Besides PureLine PQ AF, the variants on this page fall into five functional groups: basic disinfection, chlorine and chlorine dioxide removal, ozone removal, independently bioassayed assurance and the compact ECO design. All have a 316L stainless steel wetted chamber and FDA-approved wetted materials. Mikron Proses is the Nuvonic distributor in Turkey and provides application consulting for model selection.
D family: standard and hygienic basic disinfection
PureLine D AF (6 models, D AF 0003 to 0090, 115-600 W) provides basic disinfection with low pressure amalgam lamps, a wet UV monitor and a standard flanged connection; an optional tri-clamp hygienic chamber with a < 0.38 µm internal finish is available.
PureLine D EO H (3 models, D EO H 4/6/8, 4.5-6.8 kW) combines high capacity from a single medium pressure lamp with a tri-clamp hygienic chamber (< 0.8 µm Ra internal surface). It comes with a calibrated DVGW compliant dry sensor and a UVGuard window, and connects to SCADA or plant control systems through RS 485 Industrial Ethernet.
PureLine D PH (D PH 0070 to 0950, 1.6-33 kW) covers high-flow process lines with medium pressure designs of 1 to 8 lamps. Lamp life is 8,000 hours (4,000 hours for D PH 0240 and 0300), and the working fluid temperature is 1-60 °C (80 °C unwiped). It is CE marked and UL listed (E149108).
DC PH and DCD PH: chlorine and chlorine dioxide removal
PureLine DC PH (1.6-25.2 kW) removes free chlorine (HOCl and OCl⁻), and PureLine DCD PH (5 models, DCD PH 20 to 60, 4.2-25.2 kW) is designed specifically for chlorine dioxide (ClO₂) removal. Both use medium pressure lamps. Compared with activated carbon filtration or dosing of sodium metabisulphite or ferrous salt, they protect RO membranes from residual oxidant and bio-fouling without chemicals and without backwashing. Lamp life is 8,000 hours (4,000 hours for DC PH 250 and 300 and for DCD PH 40); both are CE marked and UL listed (E149108).
DO AF and DO PH: ozone removal
PureLine DO AF (3 models, DO AF 0005 to 0020, 345-700 W) uses low pressure lamps and PureLine DO PH (9 models, DO PH 0027 to 0400, 1.6-25.2 kW) uses medium pressure lamps. In source water that is ozonated to remove iron or manganese, or in process water lines, they remove residual ozone to produce deozonated water.
PQ family: independently bioassayed assurance
PQ AL (2 models, PQ AL 100/300, 2.4-7.2 kW, multi-lamp low pressure), PQ EO (5 models, PQ EO 4 to 12, 4.5-6.8 kW, single medium pressure lamp) with its hygienic variant PQ EO H+ (1 model, 9 kW, tri-clamp, < 0.8 µm) and PQ IL (6 models, PQ IL 450 to 14000, 5.6-52 kW, multi-lamp medium pressure) all come with third-party bioassayed dose equations. The PQ IL is tested in accordance with the USEPA UV Disinfection Guidance Manual. A calibrated dry UV sensor and flow and UVT meter inputs allow real-time dose calculation.
ECO: compact design with a low carbon footprint
PureLine ECO (12 models, ECO 4 to ECO 380, 4.1-385 m³/h, 90-2440 W, 1 to 7 lamps) offers a modern, compact alternative with low pressure amalgam lamps and a 7-inch touchscreen controller. It comes with a dry UV sensor, a PT100 temperature sensor and stepless 50-100% power adjustment; with the optional < 0.38 µm internal finish it can also be adapted to hygienic lines. The flow figures are the manufacturer’s capacity values under its reference conditions; the datasheet gives the details. ECO is CE marked and UL certified.
Choosing a variant
Which variant (basic or hygienic, chlorine or ozone removal, validation required or not) suits your process depends on the location of the line, the water quality and the validation requirement. Describe your application and we will select the right model together. For the selection logic, see the UV system selection guide; for maintenance, see UV lamp replacement. The whole range is listed under UV systems and on the Nuvonic brand page.
Applications
- Basic disinfection of product and process water, standard or hygienic (tri-clamp) design (D AF, D EO H, D PH)
- Protecting RO membranes from residual chlorine or chlorine dioxide and bio-fouling (DC PH, DCD PH)
- Removal of residual ozone in process or distribution water after ozonation (DO AF, DO PH)
- Third-party bioassayed assurance for critical disinfection or as a pathogen barrier (PQ AL, PQ EO, PQ EO H+, PQ IL)
- Compact industrial and commercial process water applications with a low carbon footprint (ECO)
Datasheets and manuals
- PureLine D AF Datasheet Datasheet · PDF
- PureLine D EO H Datasheet Datasheet · PDF
- PureLine D PH Datasheet Datasheet · PDF
- PureLine DC PH Datasheet Datasheet · PDF
- PureLine DCD PH Datasheet Datasheet · PDF
- PureLine DO AF Datasheet Datasheet · PDF
- PureLine DO PH Datasheet Datasheet · PDF
- PureLine PQ AL Datasheet Datasheet · PDF
- PureLine PQ EO Datasheet Datasheet · PDF
- PureLine PQ EO H+ Datasheet Datasheet · PDF
- PureLine PQ IL Datasheet Datasheet · PDF
- PureLine ECO Datasheet Datasheet · PDF
Documents were last compared with the manufacturer's source on 2026-08-21.
Other Nuvonic products
- Nuvonic Wastewater UV Disinfection (ProLine PQ WW, WW IL, OpenLine OLS) UV Systems
- Nuvonic ProLine WW IL Industrial UV System UV Systems
- Nuvonic PureLine PQ AF Food and Beverage UV System UV Systems
- Nuvonic PharmaLine ECO Pharmaceutical UV System UV Systems
- Nuvonic OpenLine OLS Series Open Channel UV System UV Systems
- Nuvonic ProLine Series Drinking Water and Wastewater Reuse UV Systems UV Systems
- Nuvonic PureLine AFX Series UV Disinfection UV Systems
- Nuvonic PureLine S PH Sugar Syrup UV System UV Systems
- RASLine Series Aquaculture UV Systems UV Systems
- SwimLine PH, PQ EO and Splash PH Swimming Pool UV Systems UV Systems
- TOCLine ECO Series TOC Reduction UV System UV Systems
- UVpro TS Submersible Water Disinfection Series UV Systems
- UVShield Pool/Spa UV Disinfection System UV Systems
- SwimLine PQ IL Swimming Pool UV System UV Systems
Send us your requirement for PureLine Series Food & Beverage UV Systems
Describe your application; we will help you identify the right model and configuration.