Hamilton Process pH and ORP Sensors in Turkey
In Turkey, Mikron Proses supplies Hamilton process pH and ORP sensors, DuraCal pH buffers, cables and immersion/retractable fittings. Mikron Proses is one of the distributors of Hamilton in Turkey and selects the pH glass and reference system for the process fluid, integrates fittings and controllers, commissions the loop and supports calibration.
Sensor family overview
Hamilton process pH/ORP sensors measure 0-14 pH and ±2000 mV (±1500 mV on Arc digital models) online. The Swiss-made electrochemical family covers polymer-gel, liquid-electrolyte and pre-pressurised designs for applications from boiler feedwater to biopharma fermentation.
Mikron Proses supplies the following Hamilton process sensor lines:
- Polilyte Plus – polymer-gel electrolyte with Single Pore open junction for chemical, water-treatment and CIP/SIP lines, including low-conductivity water
- ChemoTrode – refillable liquid electrolyte for aggressive chemistry, protein and sulphide media
- InchTrode – direct NPT-thread installation without separate fitting, for pulp & paper and chemical industry
- IonoTrode – low-resistance glass for ion-poor water down to 0.2 µS/cm
- EasyControl – economical pH/ORP for wastewater, fish farms, groundwater and swimming pools
- Liq-Glass PG – 1-12 pH sensor for water conditioning and drinking water
- EasyFerm Plus – pre-pressurised Phermlyte, autoclavable and SIP-resistant for biopharma fermentation
- OneFerm – single-use pH sensor integrated in disposable bioreactor bags
How to choose the right sensor
Selection depends on process conductivity, chemistry and cleaning regime:
| Application condition | Recommended sensor |
|---|---|
| Oily, suspension, solvent or >= 5 µS/cm low-conductivity lines | Polilyte Plus |
| Protein, sulphide or organic-solvent reactors | ChemoTrode |
| Pulp & paper and heavy industry with direct NPT mounting | InchTrode |
| Boiler feed and demineralised water down to 0.2 µS/cm | IonoTrode |
| Wastewater, fish farm and general water conditioning | EasyControl |
| Biopharma fermentation with SIP/autoclave cycles | EasyFerm Plus |
| Single-use bioreactor bags | OneFerm |
For glass selection in EasyFerm Plus: PHI glass for frequent SIP and autoclave cycles (low drift); HB glass for frequent high-alkali CIP cycles (fast response).
Key specifications
| Model | pH / ORP range | Junction / electrolyte | Min. conductivity | Temperature | Pressure | Connectors |
|---|---|---|---|---|---|---|
| Polilyte Plus H / HB / PHI | 0-14 pH (rec. 2-12) | 2x Single Pore, Everef-L, Polisolve Plus | >= 5 µS/cm | 0...130 °C | 10 bar | Arc, Memosens, VP6, S8 |
| Polilyte Plus HF | 0-14 pH, HF-resistant glass | 2x Single Pore | >= 5 µS/cm | -10...100 °C | 16 bar | — |
| Polilyte Plus XP | 0-14 pH | 2x Single Pore | >= 5 µS/cm | 0...130 °C | 50 bar at 60 °C, 20 bar at 100 °C, 16 bar at 130 °C | VP6 |
| Polilyte Plus ORP | ±2000 mV (Arc ±1500 mV) | Platinum ring, 2x Single Pore | >= 5 µS/cm | 0...130 °C | 10 bar; Arc: 16 bar at 100 °C | — |
| ChemoTrode / Bridge / P / ORP | 0-14 pH or ±2000 mV | 3x HP ceramic, 3 M KCl-LR (Skylyte on Bridge; Protelyte on P), Everef-F | >= 20 µS/cm | 0...130 °C (rec. 5...130 °C) | 6 bar | VP |
| InchTrode N75F / N75P / N100F | 0-14 pH | Single Pore ring | >= 5 µS/cm | -10...130 °C (F) / 0...130 °C (P) | 10 bar at 25 °C / 6 bar at 130 °C | REF 238346 / 238342 / 238352 |
| IonoTrode | 0-14 pH | PTFE sleeve, 3 M KCl side arm | >= 0.2 µS/cm | -10...40 °C | 0.5 bar (pressurisable) | S7, REF 238525, 120 mm |
| EasyControl pH / ORP | 0-14 pH or ±2000 mV | Ceramic | >= 20 µS/cm | 0...60 °C | 2 bar | S8, REF 238522, 120 mm |
| Liq-Glass PG | 1-12 pH | 3x ceramic | >= 2 µS/cm | -5...60 °C | 2 bar | REF 238515 |
| EasyFerm Plus PHI / HB / ORP | 0-14 pH or ±2000 mV | HP-Coatramic, Everef-F, pre-pressurised Phermlyte | >= 100 µS/cm | 0...140 °C (SIP / autoclave) | 6 bar | Arc, Memosens, VP6, S8, K8 |
| OneFerm | pH 3-10 | Integrated single-use design | — | 4-50 °C | 0-1 bar(g) | Arc Module SU pH REF 243233 |
Applications
Mikron Proses supplies Hamilton sensors for the following applications:
- Wastewater and surface treatment – acidic wastewater containing hydrofluoric acid (Polilyte Plus HF)
- High-pressure pipelines and reactors – Polilyte Plus XP
- Aggressive chemistry and pharmaceutical reactors – protein, sulphide and solvent-containing media (ChemoTrode); CIP/SIP compatible
- Pulp & paper and chemical industry – direct NPT mounting (InchTrode)
- Boiler feedwater, demineralised and drinking water – down to 0.2 µS/cm (IonoTrode)
- Wastewater, fish farms, groundwater, swimming pools – EasyControl
- Biopharma fermentation – SIP/autoclave sterilisation (EasyFerm Plus)
- Single-use bioprocessing – gamma-sterilised with bioreactor bag up to 45 kGy (OneFerm)
What Mikron Proses does
Mikron Proses selects pH glass and reference systems matched to the process fluid, integrates fittings and controllers, commissions the measurement loop and supports calibration. The company also supplies DuraCal pH buffer solutions, cables and immersion/retractable fittings including Retractex retractable fittings that allow sensor maintenance without stopping the process.
Connector options include Arc (4-20 mA + RS485 Modbus RTU with integrated microprocessor, no external transmitter needed), Memosens (MS), VP6, S8, S7, K8 and fixed cable; lengths 120, 140, 143, 150, 200, 225, 250, 325, 425 mm. Analog sensors work directly with industrial pH/ORP controllers including Walchem W100P, P100 and Intuition series. Arc sensors can be managed with ArcAir software.
How to request a quotation
Send your application data via the contact page. Include process fluid, pH range, temperature and pressure extremes, conductivity if known, cleaning regime (CIP, SIP, autoclave), required connector type and desired insertion length. Mikron Proses will select the appropriate Hamilton sensor, specify fittings and controllers, and prepare a quotation.
Frequently Asked Questions
Technical answers from Mikron Proses.
Who supplies Hamilton pH sensors in Turkey?
Mikron Proses is one of the distributors in Turkey for Hamilton process analytics. The company supplies process pH/ORP sensors, buffers, cables and fittings, and provides application selection, commissioning and calibration support.
What is the difference between EasyFerm Plus and EasyFerm Bio?
Both measure 0-14 pH, operate at 0...140 °C and 6 bar, and use HP-Coatramic junction. EasyFerm Plus uses Phermlyte for pharma/biopharma applications. EasyFerm Bio uses Foodlyte and is designed for hygienic applications (autoclavable, CIP and SIP) in food, beverage and brewery lines.
Why does the Single Pore junction resist clogging?
Single Pore has no porous ceramic. The polymer electrolyte contacts the process fluid directly through an open hole, so oil, biofilm, scale or sulphide deposits cannot block a physical pore.
Can EasyFerm Plus withstand autoclave sterilisation?
Yes. EasyFerm Plus is autoclavable and suitable for SIP and CIP within its 0...140 °C range at up to 6 bar. The pre-pressurised Phermlyte keeps internal pressure above external pressure, preventing culture-medium ingress and junction clogging.
What is the equivalent Hamilton sensor for Mettler Toledo or Endress+Hauser models?
For plants using Mettler Toledo InPro 3250/3253/4260 process pH-ORP sensors, Mikron supplies Hamilton Polilyte Plus / EasyFerm Plus as equivalent/alternative product and spare parts. For Endress+Hauser Memosens pH sensors (CPS11E/CPS41E) and Liquiline, Hamilton Memosens is available.
Planning a project? Send us your flow rate, feed water source and target water quality to [email protected] — our engineers will reply with a technical proposal.