Skip to main content
Üsküdar / İstanbul
Hamilton

Hamilton IonoTrode pH Electrode for Low-Conductivity Media

Hamilton IonoTrode is a pH electrode with an F glass membrane for ion-weak, low-conductivity media: stable measurement down to 0.2 µS/cm, PTFE sleeve diaphragm, Everef reference and a side-arm for a 3 M KCl reservoir. It is not an ion-selective electrode.

Send us your requirement

Hamilton IonoTrode pH Electrode for Low-Conductivity Media — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Measurement principlepH measurement with a combination glass electrode with a low-resistance F glass membrane (not an ion-selective electrode)
Measuring range0 to 14 pH (recommended range 0 to 13 pH)
Process temperature-10 to 40 °C
Pressure range0 to 0.5 bar, or higher if pressurized through the side-arm
Minimum conductivity0.2 µS/cm
Electrolyte3 M KCl, which can be supplied from an external vessel through the side-arm
Reference systemEveref
DiaphragmRemovable PTFE sleeve diaphragm that controls the electrolyte outflow
Connector and lengthS7; 120 mm shaft length (REF 238525)
O-ringEPDM
Electrolyte reservoirA storage container with 3 M KCl (for example the 500 mL bottle, REF 238936) is attached through a tube to the side-arm

The Hamilton IonoTrode is a pH electrode for ion-weak media with very low conductivity. It is not an ion-selective electrode: it measures pH, not a specific ion. Its F glass membrane has a very low resistance, so the sensor gives stable measurements in samples with a conductivity of at least 0.2 µS/cm. As one of Hamilton’s distributors in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies IonoTrode electrodes and provides application consulting on sensor selection.

Need a pH electrode for pure water or boiler feed water? → Send us your requirement

For the other Hamilton pH and ORP sensor families, see Hamilton pH and ORP process sensors; for general selection advice, see the pH electrode selection guide.

Sleeve diaphragm and side-arm

If a storage container with 3 M KCl is attached through a tube to the side-arm of the IonoTrode, the outflow of the electrolyte can be controlled with the PTFE sleeve diaphragm ring. The sleeve is removable, which allows the electrolyte outflow to be checked.

Key features

FeatureSpecificationBenefit
F glass membraneVery low resistanceStable measurement in samples down to 0.2 µS/cm
PTFE sleeve diaphragmRemovable ringControl and checking of the electrolyte outflow
Side-armTube to a 3 M KCl reservoirPressurization through the side-arm and electrolyte supply from an external vessel

Whether the IonoTrode fits your process depends on the sample conductivity, the temperature and the installation. Tell us about your application and we will help you choose.

Applications

  • Boiler feed water and pure water systems
  • Drinking water preparation and treatment plants
  • Continuous quality control in ion-weak process waters
  • Precise pH monitoring in low-conductivity media

Datasheets and manuals

Documents were last compared with the manufacturer's source on 2026-09-13.

Other Hamilton products

All Hamilton products →

Send us your requirement for Hamilton IonoTrode pH Electrode for Low-Conductivity Media

Describe your application; we will help you identify the right model and configuration.

Call Quote