Hamilton EasyControl pH and ORP Sensors
Hamilton EasyControl is an entry-level, maintenance-free pH and ORP sensor for chemical, wastewater and pool applications, with non-refillable gel electrolyte, Ag/AgCl reference and ceramic diaphragm.
Send us your requirementHamilton EasyControl pH and ORP Sensors — describe your application and we will help you identify the right model and configuration together.
Technical specifications
| Measuring range | EasyControl pH: 0 to 14 pH; EasyControl ORP: ± 2000 mV |
|---|---|
| Process temperature | 0 to 60 °C |
| Pressure range | 0 to 2 bar g (relative to ambient) |
| pH glass | HF glass (EasyControl pH) |
| ORP element | Platinum wire |
| Electrolyte | Gel electrolyte in a non-refillable design |
| Reference system | Ag/AgCl |
| Diaphragm | Ceramic |
| O-ring | EPDM |
| Connector and length | S8, 120 mm shaft length (REF 238522, non-Ex) |
The Hamilton EasyControl is an entry-level pH and ORP sensor with a non-refillable gel electrolyte for chemical and wastewater applications at low process temperatures. It measures 0 to 14 pH (EasyControl pH) or ± 2000 mV (EasyControl ORP) at 0 to 60 °C and up to 2 bar g. Hamilton notes good behavior in samples with low conductivity. As one of Hamilton’s distributors in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies EasyControl sensors and provides application consulting on sensor selection.
Need a pH or ORP sensor for wastewater, a pool or a dosing line? → Send us your requirement
For the other Hamilton pH and ORP sensor families, see Hamilton pH and ORP process sensors; for general selection advice, see the pH electrode selection guide.
Easy maintenance
The gel electrolyte cannot be refilled, so the sensor needs no electrolyte maintenance: Hamilton lists easy maintenance due to the non-refillable electrolyte as a benefit. In addition to the pH model, an EasyControl ORP model with a platinum wire sensing element is available for redox monitoring and swimming pool chlorination control.
EasyControl model comparison
| Model | Measuring range | Process temperature | Reference and electrolyte |
|---|---|---|---|
| EasyControl pH | 0 to 14 pH | 0 to 60 °C | Ag/AgCl, HF glass, gel electrolyte |
| EasyControl ORP | ± 2000 mV | 0 to 60 °C | Ag/AgCl, platinum wire, gel electrolyte |
| Liq-Glass PG | 1 to 12 pH | -5 to 60 °C | Everef, F glass, 3 ceramic diaphragms |
Liq-Glass PG is a related entry-level sensor from the same catalog page: it has three ceramic diaphragms for reduced flow potentials and uses a viscous 3 M KCl-LR electrolyte.
Which sensor fits your process depends on the medium, the temperature and the installation. Tell us about your application and we will help you choose.
Applications
- Industrial and municipal wastewater treatment plants
- Chemical dosing lines and neutralization processes
- Chlorination and pH/ORP disinfection control in swimming pools
- Fish farming (aquaculture) and surface water monitoring
- Low-conductivity water samples and groundwater monitoring
Datasheets and manuals
Documents were last compared with the manufacturer's source on 2026-09-13.
Other Hamilton products
- Hamilton Arc Peripherals and ArcAir Software (Arc View Mobile, Arc Wi Pivot, Arc USB, ArcAir) Online Measurement and Automation Systems
- Hamilton ChemoTrode pH Sensors for Aggressive Media pH and ORP Sensors
- Hamilton CO2NTROL Solid-State Optical Dissolved CO2 Sensor Online Measurement and Automation Systems
- Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions Online Measurement and Automation Systems
- Hamilton Bioprocess pH Sensors (EasyFerm Plus, EasyFerm Bio and OneFerm) pH and ORP Sensors
- Hamilton GlucoSense In-Situ Optical Glucose Sensor for Bioreactors Online Measurement and Automation Systems
- Hamilton Cell Density Sensors (InCyte / Dencytee) Online Measurement and Automation Systems
- Hamilton Conductivity Sensors Conductivity Sensors
- Hamilton InchTrode pH Electrode pH and ORP Sensors
- Hamilton Incyte Arc Viable Cell Density Sensor Online Measurement and Automation Systems
- Hamilton IonoTrode pH Electrode for Low-Conductivity Media pH and ORP Sensors
- Hamilton Calibration Solutions (DuraCal pH and ORP Buffers and Conductivity Standards) Online Measurement and Automation Systems
- Hamilton Laboratory pH and ORP Electrodes (GLP Series) Online Measurement and Automation Systems
- Hamilton Process Analytics, Liquid Handling and Laboratory Solutions Online Measurement and Automation Systems
- Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps Online Measurement and Automation Systems
- Hamilton MecoTrode pH Electrode Hamilton pH and ORP Process Sensors
- Hamilton OEM Sensors and Sensor Accessories Online Measurement and Automation Systems
- Hamilton Oxygen Sensor Accessories (Oxylyte Electrolyte, Membrane Kits, Calibration Station) Hamilton Dissolved Oxygen Sensors
- Hamilton OneFerm pH Single-Use pH Sensor Hamilton pH and ORP Process Sensors
- Hamilton Polilyte Plus pH Sensors Hamilton pH and ORP Process Sensors
- Hamilton Process Fittings and Flow Cells (FlexiFit, StatoFlex, FlowChamber, FlowCell, FlexiFlow, MasterFit) Online Measurement and Automation Systems
- Hamilton Retractex Retractable Sensor Housings Online Measurement and Automation Systems
- Hamilton Precision Syringes, Needles and Chromatography Accessories Online Measurement and Automation Systems
- Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors Hamilton Dissolved Oxygen Sensors
Send us your requirement for Hamilton EasyControl pH and ORP Sensors
Describe your application; we will help you identify the right model and configuration.