Hamilton InchTrode pH Electrode
Hamilton InchTrode is a pH electrode with a robust PEEK shaft for direct pipe mounting in pulp and paper, chemical and wastewater processes: Polisolve polymer electrolyte, Single Pore junction and NPT thread.
Send us your requirementHamilton InchTrode pH Electrode — describe your application and we will help you identify the right model and configuration together.
Technical specifications
| Measuring range | 0 to 14 pH |
|---|---|
| Process temperature | Flat membrane: -10 to 130 °C; cylindrical membrane: 0 to 130 °C |
| Pressure range | 0 to 10 bar g at 25 °C; 0 to 6 bar g at 130 °C |
| Shaft | Robust PEEK shaft |
| Liquid junction | Single Pore, with direct contact between sample and electrolyte |
| Electrolyte | Polisolve polymer electrolyte |
| Reference system | Everef-L |
| pH glass | HF (flat membrane) or PHI (cylindrical membrane) |
| Temperature sensor | Pt1000 in the VP version; Pt100 in the fixed-cable version |
| Process connection | 3/4-inch NPT (N75) or 1-inch NPT (N100) |
| Connector options | VP6 or fixed cable |
The Hamilton InchTrode is a pH electrode for demanding applications in paper making, the chemical industry and wastewater treatment. It has a robust PEEK shaft and an integrated NPT process thread, so it can be installed without an additional housing, directly in pipelines or pilot plants. As one of Hamilton’s distributors in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies InchTrode electrodes and provides application consulting on sensor selection.
Need a pH electrode for a pipeline or a pulp process? → Send us your requirement
For the other Hamilton pH and ORP sensor families, see Hamilton pH and ORP process sensors; for general selection advice, see the pH electrode selection guide.
Single Pore junction and Polisolve electrolyte
The Single Pore liquid junction gives direct contact between the sample and the Polisolve polymer electrolyte. Hamilton lists this as a clog-free design with a very long-lasting reference system, which suits fibrous and particle-laden media. The flat membrane (HF glass) is the choice for abrasive flows, while the cylindrical membrane (PHI glass) suits applications where periodic CIP cleaning is necessary.
InchTrode model options
| Model | Process connection | Membrane | Temperature and pressure |
|---|---|---|---|
| InchTrode N75F | 3/4-inch NPT | Flat membrane (HF glass) | -10 to 130 °C / 10 bar g (25 °C) |
| InchTrode N75P | 3/4-inch NPT | Cylindrical membrane (PHI glass) | 0 to 130 °C / 10 bar g (25 °C) |
| InchTrode N100F | 1-inch NPT | Flat membrane (HF glass) | -10 to 130 °C / 10 bar g (25 °C) |
Versions with a fixed cable (N75FC10 and N75PC10) use a Pt100 temperature sensor; the VP6 versions use Pt1000.
Which InchTrode model fits your pipeline depends on the thread size, the membrane type and the process conditions. Tell us about your application and we will help you choose.
Applications
- Pulp and paper industry
- Narrow installation spaces, small pipelines and pilot plants
- Industrial water and wastewater neutralization lines
- Direct pipeline installation without additional housing
Datasheets and manuals
- Hamilton Process Analytics Catalog 2024 Catalog · PDF
- Hamilton InchTrode pH Sensor Operating Manual User manual · PDF
Documents were last compared with the manufacturer's source on 2026-09-13.
Other Hamilton products
- Hamilton Arc Peripherals and ArcAir Software (Arc View Mobile, Arc Wi Pivot, Arc USB, ArcAir) Online Measurement and Automation Systems
- Hamilton ChemoTrode pH Sensors for Aggressive Media pH and ORP Sensors
- Hamilton CO2NTROL Solid-State Optical Dissolved CO2 Sensor Online Measurement and Automation Systems
- Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions Online Measurement and Automation Systems
- Hamilton EasyControl pH and ORP Sensors pH and ORP Sensors
- Hamilton Bioprocess pH Sensors (EasyFerm Plus, EasyFerm Bio and OneFerm) pH and ORP Sensors
- Hamilton GlucoSense In-Situ Optical Glucose Sensor for Bioreactors Online Measurement and Automation Systems
- Hamilton Cell Density Sensors (InCyte / Dencytee) Online Measurement and Automation Systems
- Hamilton Conductivity Sensors Conductivity Sensors
- Hamilton Incyte Arc Viable Cell Density Sensor Online Measurement and Automation Systems
- Hamilton IonoTrode pH Electrode for Low-Conductivity Media pH and ORP Sensors
- Hamilton Calibration Solutions (DuraCal pH and ORP Buffers and Conductivity Standards) Online Measurement and Automation Systems
- Hamilton Laboratory pH and ORP Electrodes (GLP Series) Online Measurement and Automation Systems
- Hamilton Process Analytics, Liquid Handling and Laboratory Solutions Online Measurement and Automation Systems
- Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps Online Measurement and Automation Systems
- Hamilton MecoTrode pH Electrode Hamilton pH and ORP Process Sensors
- Hamilton OEM Sensors and Sensor Accessories Online Measurement and Automation Systems
- Hamilton Oxygen Sensor Accessories (Oxylyte Electrolyte, Membrane Kits, Calibration Station) Hamilton Dissolved Oxygen Sensors
- Hamilton OneFerm pH Single-Use pH Sensor Hamilton pH and ORP Process Sensors
- Hamilton Polilyte Plus pH Sensors Hamilton pH and ORP Process Sensors
- Hamilton Process Fittings and Flow Cells (FlexiFit, StatoFlex, FlowChamber, FlowCell, FlexiFlow, MasterFit) Online Measurement and Automation Systems
- Hamilton Retractex Retractable Sensor Housings Online Measurement and Automation Systems
- Hamilton Precision Syringes, Needles and Chromatography Accessories Online Measurement and Automation Systems
- Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors Hamilton Dissolved Oxygen Sensors
Send us your requirement for Hamilton InchTrode pH Electrode
Describe your application; we will help you identify the right model and configuration.