Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions

Hamilton DuraCal pH buffer solutions traceable to NIST and PTB and certified by DAkkS, with stability of up to five years, plus ORP buffers (271 mV and 475 mV) and DFM-certified conductivity standards from 1.3 µS/cm.

Send us your requirement

Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions — describe your application and we will help you identify the right model and configuration together.

Technical specifications

pH buffer valuespH 1.09, 1.68, 2.00, 3.06, 4.01, 5.00, 6.00, 7.00, 8.00, 9.21, 10.01, 11.00 and 12.00
pH accuracy and stabilitypH 4.01 / 7.00 / 10.01 set (REF 238924): ±0.01 pH with 24 months stability and ±0.02 pH with 60 months stability after the date of manufacturing; DAkkS certificate
TraceabilityClosed-loop (top-down and bottom-up) traceability to NIST (USA) and PTB (Germany); a DAkkS calibration certificate for every DuraCal production batch
Alkaline buffer stabilityThe pH 9.21 and 10.01 buffers are stable even when exposed to air
Bottle design250 mL and 500 mL bottles with a built-in calibration compartment; only 15 mL of buffer is used per calibration
Three-buffer sets3 x 500 mL sets: pH 4.01 / 7.00 / 9.21 (REF 238922) and pH 4.01 / 7.00 / 10.01 (REF 238924)
ORP buffers271 mV (REF 238228) and 475 mV (REF 238227 and 238322); ±5 mV accuracy; 24 months stability
Conductivity standards1.3, 5, 15, 84, 100, 147, 706, 1413 and 12,880 µS/cm and 100 mS/cm; ±1% certified accuracy (±2% at 706 µS/cm); 12 to 36 months stability depending on value and bottle; DFM certificate
Open bottle timeConductivity standard bottles may stay open for a total of 60 minutes

Hamilton DuraCal buffer solutions calibrate process and laboratory pH, ORP and conductivity sensors with certified, traceable reference solutions. The pH buffers are traceable to the primary standards of NIST (USA) and PTB (Germany) through a closed-loop chain and carry a DAkkS calibration certificate for every production batch. Hamilton states a pH stability of up to five years and an accuracy of up to ±0.01 pH. As one of Hamilton’s distributors in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies DuraCal pH, ORP and conductivity solutions and provides application consulting on calibration.

Need pH, ORP or conductivity calibration solutions? → Send us your requirement

The sensors these solutions calibrate are described in Hamilton pH and ORP process sensors, the EasyFerm Plus, EasyFerm Bio and OneFerm pH sensors, Hamilton Conducell conductivity sensors and the Arc peripherals and ArcAir page. A shorter overview of the whole range is on the calibration solutions page.

pH buffers and traceability

Hamilton works with circular, closed-loop traceability. Top-down, the buffer value is determined against secondary reference solutions that are themselves compared against primary solutions from PTB or NIST. Bottom-up, a representative number of samples from every production lot is verified by an independent DAkkS laboratory, which closes the loop.

The pH 4.01 / 7.00 / 10.01 set (REF 238924) is a three-buffer set for calibration at common pH levels; each liquid solution comes with a certificate and serves as a Certified Reference Material. The datasheet gives the accuracy and stability as ±0.01 pH for 24 months or ±0.02 pH for 60 months after the date of manufacturing, and a storage range of 5 to 35 °C.

Buffer250 mL bottle (REF)500 mL bottle (REF)3 x 500 mL (REF)
pH 4.01238317238217238917
pH 7.00238318238218238918
pH 9.21238319238219238919
pH 10.01238321238223238923

The other pH values (1.09, 1.68, 2.00, 3.06, 5.00, 6.00, 8.00, 11.00 and 12.00) are available in 500 mL bottles. The pH 9.21 and 10.01 buffers are stable even when exposed to air.

ORP buffers

ValueAccuracyStabilityPackage (REF)
271 mV±5 mV24 months500 mL (238228)
475 mV±5 mV24 months250 mL (238322), 500 mL (238227)

Conductivity standards

Because a conductivity standard is not a buffer, absorption of CO2 or contamination shifts low values easily. Hamilton states that it is the first manufacturer to offer patented standards of 1.3 and 5 µS/cm with a certified accuracy of ±1%. The standards come with a certificate from DFM, the Danish Institute of Fundamental Metrology, and are developed in collaboration with it.

Value at 25 °CAccuracyStability (months)Package (REF)
1.3 µS/cm±1%12250 mL glass bottle (238973)
5 µS/cm±1%36250 mL glass bottle (238926)
15 µS/cm±1%36250 mL glass bottle (238927)
84 µS/cm±1%18500 mL Calpack bottle (238984)
100 µS/cm±1%36250 mL glass bottle (238934)
147 µS/cm±1%18500 mL Calpack bottle (238985)
706 µS/cm±2%36250 mL glass bottle (238929)
1413 µS/cm±1%36 / 18250 mL glass bottle (238928) / 500 mL Calpack bottle (238986)
12,880 µS/cm±1%18500 mL Calpack bottle (238988)
100 mS/cm±1%36250 mL glass bottle (238935)

Bottles may stay open for a total of 60 minutes. For background on pure water conductivity measurement under USP 645, see the pure water conductivity and USP 645 guide.

Electrolytes, storage and cleaning

For electrode care Hamilton also offers 3 M KCl storage and refill solution, the reference electrolytes Skylyte and Protelyte, and a cleaning solution set (REF 238290) for the pH glass and the diaphragm.


Which pH, ORP and conductivity values you need depends on the sensors to calibrate, the calibration frequency and your regulatory requirements. Tell us about your sensors and we will define the right solution set together.

Applications

  • Traceable pH and ORP calibration for FDA and GMP audits in biopharma and pharmaceutical production
  • Verification of low-conductivity standards (1.3 µS/cm and 5 µS/cm) in WFI and ultra-pure water loops under USP 645
  • Field and laboratory calibration with automatic buffer recognition in Hamilton ArcAir
  • Storage (3 M KCl), diaphragm cleaning and regeneration care of pH electrodes