Hamilton Conducell conductivity sensors from the product catalog
Conducell 4UxF measuring rangeAnalog: 1 µS/cm to 500 mS/cm; Arc: 1 µS/cm to 300 mS/cm; 4-pole contacting; wetted parts are FDA compliant; CIP, SIP and autoclave compatible
Conducell 4UxF materials and connectionElectrode material stainless steel 1.4435 (4USF), Hastelloy C 2.4602, titanium or platinum; Arc or VP output; shaft lengths from 30 to 425 mm with PG 13.5 or a 1.5-inch Tri-Clamp
Conducell 4US-T150 (0.147/cm)Cell constant 0.147/cm; -20 to 135 °C, up to 6 bar g; CIP and SIP; FDA compliant wetted parts
Conducell 4USF-VV (0.36/cm)Cell constant 0.36/cm; up to 20 bar g at 135 °C; autoclavable, CIP and SIP; FDA compliant; VP output
Conducell UPW measuring rangeArc: 0.01 to 1500 µS/cm (analog: 0.02 to 2000 µS/cm); for ultra-pure water, pure water and water for injection
Conducell UPW temperature and pressureArc: 0 to 110 °C with the analog interface and 0 to 130 °C with the digital interface; up to 10 bar g at 130 °C; autoclavable, CIP and SIP
Conducell UPW complianceUSP 645, EP, JP and FDA compliant; the Traditional model is ATEX and IECEx approved; PG 13.5 (120 mm) or 1.5-inch Tri-Clamp (87 mm) process connection; VP or Arc output
Conducell UPW Arc verificationTraceable UPW Simulator (REF 243580) to verify the Arc module in accordance with USP 645
2-pole Conducell 2DC-PGCell constant 1/cm; 10 µS/cm to 20 mS/cm; -5 to 80 °C, up to 6 bar g

Hamilton’s process conductivity range covers the wide-range, 4-pole Conducell 4UxF family and the Conducell UPW family for ultra-pure water. The 4UxF measures from 1 µS/cm up to 500 mS/cm on the analog version (300 mS/cm on Arc) with FDA-compliant wetted parts and CIP, SIP and autoclave compatibility. The UPW measures 0.01 to 1500 µS/cm on the Arc version and complies with USP 645, EP, JP and FDA. As one of Hamilton’s distributors in Turkey, Mikron Proses (Üsküdar, Istanbul) supplies Conducell sensors and provides application consulting on sensor selection.

Need a conductivity sensor for a CIP line or a water loop? → Send us your requirement

For the product group overview, see Hamilton Conducell conductivity sensors; for pure water measurement background, see the pure water conductivity and USP 645 guide. Field verification uses the standards on the Hamilton calibration solutions page.

Conducell 4UxF: 4-pole, wide-range measurement

The Conducell 4UxF covers trace to very high conductivity on one platform. All wetted parts (DIN 1.4435, PEEK, EPDM) are FDA compliant and withstand CIP, SIP and autoclaving. The model code letter selects the electrode material: stainless steel 1.4435 (4USF), Hastelloy C 2.4602, titanium or platinum.

The cell constant depends on the model. The Conducell 4US-T150 family has a cell constant of 0.147/cm, works from -20 to 135 °C up to 6 bar g, and is CIP and SIP compatible with FDA-compliant wetted parts. The Conducell 4USF-VV has a cell constant of 0.36/cm, withstands up to 20 bar g at 135 °C and is autoclavable, CIP and SIP compatible, with VP output.

Conducell UPW: ultra-pure water and USP 645

The Conducell UPW is a 2-pole sensor for ultra-pure water, pure water and water for injection. The Arc version measures 0.01 to 1500 µS/cm, up to 130 °C with the digital interface and up to 10 bar g at 130 °C; it is autoclavable and compatible with CIP and SIP. It complies with USP 645, EP, JP and FDA, and the Traditional model is ATEX and IECEx approved. Process connections are PG 13.5 or a 1.5-inch Tri-Clamp, with VP or Arc output. On the Arc version, the Arc module is calibrated with a traceable UPW Simulator (REF 243580) to verify USP 645 compliance in the field.

Cell constant and model selection

Alongside the 4-pole family, the catalog includes the simpler 2-pole Conducell 2DC-PG, with a cell constant of 1/cm, a range of 10 µS/cm to 20 mS/cm, -5 to 80 °C and up to 6 bar g. The right model depends on the conductivity range (from trace UPW to concentrated CIP solutions), the process temperature and pressure and the process connection (PG 13.5, Tri-Clamp).


Which Conducell family and cell constant fit your process depends on the measuring range, the temperature and pressure and regulatory requirements such as ATEX and USP 645. Tell us about your application and we will define the right sensor together.

Applications

  • Continuous in-line conductivity monitoring in CIP and SIP lines and process water systems
  • USP 645 compliant measurement in ultra-pure water and water for injection (WFI) loops
  • Wide-range measurement from trace to high conductivity in pharmaceutical and chemical processes
  • Hazardous-area UPW lines (Conducell UPW ATEX and IECEx Traditional models)
  • Integration into existing Modbus RS485 and 4-20 mA automation through the Arc digital output

Datasheets and manuals