Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors
Hamilton dissolved oxygen (DO) sensors for in-line process measurement: optical VisiFerm, VisiTrace and VisiWater sensors based on oxygen-dependent luminescence, and electrochemical OxyFerm FDA, OxyGold B, OxyGold G and Oxysens sensors, covering ranges from 1 ppb to 40 ppm.
Send us your requirementHamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors — describe your application and we will help you identify the right model and configuration together.
Technical specifications

| Optical DO sensors | VisiFerm RS485 and VisiFerm mA (4 ppb to 25 ppm; 0 to 300 %-sat) · VisiTrace mA and RS485 (0 to 2000 ppb trace oxygen) · VisiWater DO P Arc (up to 40 ppm, for water and wastewater) |
|---|---|
| Amperometric DO sensors | OxyFerm FDA (10 ppb to 40 ppm, hygienic) · OxyGold G (1 ppb to 40 ppm, trace oxygen) · OxyGold B (8 ppb to 40 ppm, 0 mV polarization voltage, no cross-sensitivity with CO2) · Oxysens (40 ppb to 40 ppm, no change of membrane or electrolyte) |
| Measuring principle | Optical: oxygen-dependent luminescence, flow independent. Amperometric: electrochemical reduction of oxygen, response time below 60 s at 25 °C |
| Process temperature | VisiFerm and VisiTrace: up to 140 °C for autoclaving, CIP and SIP, with a measurement temperature range of -10 to 85 °C · OxyFerm FDA and OxyGold G: 0 to 130 °C · OxyGold B: 0 to 100 °C · Oxysens and VisiWater: 0 to 60 °C |
| Pressure range | VisiFerm, VisiTrace, VisiWater, OxyGold B and OxyGold G: up to 12 bar · OxyFerm FDA and Oxysens: 0 to 4 bar g |
| Material and surface | Stainless steel 1.4435, surface quality Ra < 0.4 µm (N5); Oxysens Ra < 0.8 µm (N6); EPDM o-ring; VisiWater with a PVC-U shaft |
| Connectors and output | Arc (digital RS485 and 4-20 mA family), VisiFerm mA and VisiTrace mA (2-wire 4-20 mA with HART, ATEX / IECEx), VP6, T82, Memosens (MS) depending on the model; Oxysens with a 5 m fixed cable (REF 237150) |
| Original DO accessories | ODO Cap (H0, H2, H3, H4, L1, H20), Membrane Kit (OxyFerm REF 237123, FDA REF 237140, CIP REF 237126, OxyGold REF 237135), Oxylyte / Oxylyte G / Oxylyte B (REF 237118 / 237139 / 237138), Polarization Module T / G / B |
Hamilton offers dissolved oxygen (DO) sensors for in-line measurement with two technologies. The optical VisiFerm, VisiTrace and VisiWater sensors work on oxygen-dependent luminescence, and the electrochemical (amperometric) OxyFerm FDA, OxyGold G, OxyGold B and Oxysens sensors work on the electrochemical reduction of oxygen. Together they cover measuring ranges from 1 ppb up to 40 ppm. Mikron Proses (Üsküdar, Istanbul) supplies Hamilton process sensors in Turkey and provides application consulting on sensor selection, housing integration and commissioning.
Hamilton dissolved oxygen sensors → See the Hamilton DO product family | Send us your requirement
Hamilton DO sensor families compared
Whether the optical or the amperometric principle fits a process depends on the expected oxygen concentration (ppb trace level or ppm aeration level), the sterilization temperature (CIP/SIP) and the presence of carbon dioxide.
| Sensor | Principle | Measuring range (DO) | Nominal / measurement temperature | Max. pressure (bar) | Compatible ODO Cap / membrane kit |
|---|---|---|---|---|---|
| VisiFerm RS485 (Arc) | Optical | 4 ppb to 25 ppm | -10 to 140 °C / -10 to 85 °C | 12 | ODO Cap H0, H2, H3, H4 |
| VisiFerm mA | Optical | 4 ppb to 25 ppm | -10 to 140 °C / -10 to 85 °C | 12 | ODO Cap H3, H4 |
| VisiTrace mA / RS485 | Optical | 0 to 2000 ppb | -10 to 140 °C / -10 to 85 °C | 12 | ODO Cap L1 |
| VisiWater DO P Arc | Optical | up to 40 ppm | 0 to 60 °C | 12 | ODO Cap H20 |
| OxyFerm FDA | Amperometric | 10 ppb to 40 ppm | 0 to 130 °C | 4 | Membrane Kit FDA, CIP and standard |
| OxyGold G | Amperometric | 1 ppb to 40 ppm | 0 to 130 °C | 12 | OxyGold Membrane Kit and Oxylyte G |
| OxyGold B | Amperometric | 8 ppb to 40 ppm | 0 to 100 °C | 12 | OxyGold Membrane Kit and Oxylyte B |
| Oxysens | Amperometric | 40 ppb to 40 ppm | 0 to 60 °C | 4 | No membrane or electrolyte change |
Optical or amperometric: how to choose
VisiFerm and VisiTrace optical sensors
The VisiFerm sensor is delivered ready to use without the need for polarization. It is flow independent and has no CO2 fouling issues. VisiFerm mA is a 2-wire sensor with 4-20 mA and HART output for use in explosive environments (ATEX / IECEx). The VisiTrace sensors, with the special ODO Cap L1, are designed to measure ppb levels of dissolved oxygen, and they are listed for power plants. Only the ODO Cap is renewed periodically; there is no liquid electrolyte to refill.
OxyGold G and OxyGold B
OxyGold G is designed for processes in which very small amounts of oxygen have to be traced, such as in the pharmaceutical or microelectronics industry and in boiler feed water. It is suitable for use at high temperatures and high pressures during sterilization and CIP, and its cathode can be replaced (REF 237395 for 120 mm VP6, REF 237396 for 225 mm VP6, REF 243110 and REF 243111 for the Arc versions).
OxyGold B (REF 237180 for 120 mm, REF 237185 for 225 mm) is the sensor for applications that contain carbon dioxide, such as the production of beer, sparkling wine and soft drinks, and for CO2 recovery. It works with a polarization voltage of 0 mV and Oxylyte B electrolyte, so there is no cross-sensitivity with CO2. According to the operating instructions, the electrolyte fill is 1.5 mL and the sensor must not be tightened above 1.5 Nm in the housing.
Oxysens
Oxysens (REF 237150, 120 mm shaft, 5 m fixed cable) is designed for water applications such as wastewater treatment, swimming pools and fish farms. The membrane and the electrolyte do not need to be replaced, the response time is fast and it is insensitive to soiling. For open channels and streams, the Immersing Set (REF 237158) sheaths and protects the sensor while it is immersed.
Original Hamilton DO accessories
| Accessory | Description | Compatible sensor | REF |
|---|---|---|---|
| ODO Cap H0 / H2 / H3 / H4 | Optical measuring cap | VisiFerm RS485 (H0, H2, H3, H4); VisiFerm mA (H3, H4) | H0, H2, H3, H4 |
| ODO Cap L1 / H20 | Trace oxygen cap (L1) and water/wastewater cap (H20) | VisiTrace (L1); VisiWater DO P Arc (H20) | L1, H20 |
| OxyFerm Membrane Kit | 3 membrane bodies, Oxylyte, pipette, spare o-ring, polishing strip | OxyFerm | 237123 |
| Membrane Kit FDA | 3 FDA membrane bodies with rounded design | OxyFerm FDA | 237140 |
| Membrane Kit CIP | 3 membrane bodies for CIP cleanings | OxyFerm CIP / FDA | 237126 |
| OxyGold Membrane Kit | 3 membrane bodies, pipette, spare o-ring (electrolyte ordered separately) | OxyGold G, OxyGold B | 237135 |
| Oxylyte electrolytes | Oxylyte, Oxylyte G, Oxylyte B | OxyFerm / OxyGold G / OxyGold B | 237118 / 237139 / 237138 |
| Polarization Module T / G / B | Prepares replacement sensors for immediate use | OxyFerm (T), OxyGold G (G), OxyGold B (B) | 237370 / 237350 / 237360 |
| Replacement cathode | Replaceable cathode | OxyFerm / OxyGold G / OxyGold B | 237306 / 237427 / 237437 |
| Autoclavation Cap / Immersing Set | Connector protection for autoclavation / protection for 120 mm sensors in channels | OxyFerm (T82) / Oxysens | 242000 / 237158 |
For the maintenance items in more detail, see Hamilton oxygen sensor accessories. For background on optical measurement, see the optical dissolved oxygen sensor guide and the guide to dissolved oxygen in boiler water. For retractable housings that allow calibration without stopping the process, see Hamilton Retractex housings.
Applications
- CIP/SIP-compatible dissolved oxygen control in bioreactor and fermentation lines (VisiFerm, OxyFerm FDA)
- Trace oxygen measurement in beer, sparkling wine, soft drinks and CO2 recovery plants (OxyGold B, with 0 mV polarization voltage)
- Trace oxygen monitoring in boiler feed water and in pharmaceutical and microelectronics processes (OxyGold G, VisiTrace)
- Dissolved oxygen monitoring in wastewater treatment and fish farms (Oxysens, VisiWater DO P Arc)
Datasheets and manuals
- Hamilton OxyGold B Dissolved Oxygen Sensor Operating Instructions (REF 237180 / 237185) User manual · PDF
- Hamilton Process Analytics Catalog 2024 Catalog · PDF
Documents were last compared with the manufacturer's source on 2026-11-03.
Other Hamilton products
- Hamilton Arc Peripherals and ArcAir Software (Arc View Mobile, Arc Wi Pivot, Arc USB, ArcAir) Online Measurement and Automation Systems
- Hamilton ChemoTrode pH Sensors for Aggressive Media pH and ORP Sensors
- Hamilton CO2NTROL Solid-State Optical Dissolved CO2 Sensor Online Measurement and Automation Systems
- Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions Online Measurement and Automation Systems
- Hamilton EasyControl pH and ORP Sensors pH and ORP Sensors
- Hamilton Bioprocess pH Sensors (EasyFerm Plus, EasyFerm Bio and OneFerm) pH and ORP Sensors
- Hamilton GlucoSense In-Situ Optical Glucose Sensor for Bioreactors Online Measurement and Automation Systems
- Hamilton Cell Density Sensors (InCyte / Dencytee) Online Measurement and Automation Systems
- Hamilton Conductivity Sensors Conductivity Sensors
- Hamilton InchTrode pH Electrode pH and ORP Sensors
- Hamilton Incyte Arc Viable Cell Density Sensor Online Measurement and Automation Systems
- Hamilton IonoTrode pH Electrode for Low-Conductivity Media pH and ORP Sensors
- Hamilton Calibration Solutions (DuraCal pH and ORP Buffers and Conductivity Standards) Online Measurement and Automation Systems
- Hamilton Laboratory pH and ORP Electrodes (GLP Series) Online Measurement and Automation Systems
- Hamilton Process Analytics, Liquid Handling and Laboratory Solutions Online Measurement and Automation Systems
- Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps Online Measurement and Automation Systems
- Hamilton MecoTrode pH Electrode Hamilton pH and ORP Process Sensors
- Hamilton OEM Sensors and Sensor Accessories Online Measurement and Automation Systems
- Hamilton Oxygen Sensor Accessories (Oxylyte Electrolyte, Membrane Kits, Calibration Station) Hamilton Dissolved Oxygen Sensors
- Hamilton OneFerm pH Single-Use pH Sensor Hamilton pH and ORP Process Sensors
- Hamilton Polilyte Plus pH Sensors Hamilton pH and ORP Process Sensors
- Hamilton Process Fittings and Flow Cells (FlexiFit, StatoFlex, FlowChamber, FlowCell, FlexiFlow, MasterFit) Online Measurement and Automation Systems
- Hamilton Retractex Retractable Sensor Housings Online Measurement and Automation Systems
- Hamilton Precision Syringes, Needles and Chromatography Accessories Online Measurement and Automation Systems
Send us your requirement for Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors
Describe your application; we will help you identify the right model and configuration.