Skip to main content
Üsküdar / İstanbul
Hamilton

Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors

Hamilton dissolved oxygen (DO) sensors for in-line process measurement: optical VisiFerm, VisiTrace and VisiWater sensors based on oxygen-dependent luminescence, and electrochemical OxyFerm FDA, OxyGold B, OxyGold G and Oxysens sensors, covering ranges from 1 ppb to 40 ppm.

Send us your requirement

Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Hamilton VisiFerm optical and OxyGold / Oxysens dissolved oxygen sensor family, representative image
Optical DO sensorsVisiFerm RS485 and VisiFerm mA (4 ppb to 25 ppm; 0 to 300 %-sat) · VisiTrace mA and RS485 (0 to 2000 ppb trace oxygen) · VisiWater DO P Arc (up to 40 ppm, for water and wastewater)
Amperometric DO sensorsOxyFerm FDA (10 ppb to 40 ppm, hygienic) · OxyGold G (1 ppb to 40 ppm, trace oxygen) · OxyGold B (8 ppb to 40 ppm, 0 mV polarization voltage, no cross-sensitivity with CO2) · Oxysens (40 ppb to 40 ppm, no change of membrane or electrolyte)
Measuring principleOptical: oxygen-dependent luminescence, flow independent. Amperometric: electrochemical reduction of oxygen, response time below 60 s at 25 °C
Process temperatureVisiFerm and VisiTrace: up to 140 °C for autoclaving, CIP and SIP, with a measurement temperature range of -10 to 85 °C · OxyFerm FDA and OxyGold G: 0 to 130 °C · OxyGold B: 0 to 100 °C · Oxysens and VisiWater: 0 to 60 °C
Pressure rangeVisiFerm, VisiTrace, VisiWater, OxyGold B and OxyGold G: up to 12 bar · OxyFerm FDA and Oxysens: 0 to 4 bar g
Material and surfaceStainless steel 1.4435, surface quality Ra < 0.4 µm (N5); Oxysens Ra < 0.8 µm (N6); EPDM o-ring; VisiWater with a PVC-U shaft
Connectors and outputArc (digital RS485 and 4-20 mA family), VisiFerm mA and VisiTrace mA (2-wire 4-20 mA with HART, ATEX / IECEx), VP6, T82, Memosens (MS) depending on the model; Oxysens with a 5 m fixed cable (REF 237150)
Original DO accessoriesODO Cap (H0, H2, H3, H4, L1, H20), Membrane Kit (OxyFerm REF 237123, FDA REF 237140, CIP REF 237126, OxyGold REF 237135), Oxylyte / Oxylyte G / Oxylyte B (REF 237118 / 237139 / 237138), Polarization Module T / G / B

Hamilton offers dissolved oxygen (DO) sensors for in-line measurement with two technologies. The optical VisiFerm, VisiTrace and VisiWater sensors work on oxygen-dependent luminescence, and the electrochemical (amperometric) OxyFerm FDA, OxyGold G, OxyGold B and Oxysens sensors work on the electrochemical reduction of oxygen. Together they cover measuring ranges from 1 ppb up to 40 ppm. Mikron Proses (Üsküdar, Istanbul) supplies Hamilton process sensors in Turkey and provides application consulting on sensor selection, housing integration and commissioning.

Hamilton dissolved oxygen sensors → See the Hamilton DO product family | Send us your requirement

Hamilton DO sensor families compared

Whether the optical or the amperometric principle fits a process depends on the expected oxygen concentration (ppb trace level or ppm aeration level), the sterilization temperature (CIP/SIP) and the presence of carbon dioxide.

SensorPrincipleMeasuring range (DO)Nominal / measurement temperatureMax. pressure (bar)Compatible ODO Cap / membrane kit
VisiFerm RS485 (Arc)Optical4 ppb to 25 ppm-10 to 140 °C / -10 to 85 °C12ODO Cap H0, H2, H3, H4
VisiFerm mAOptical4 ppb to 25 ppm-10 to 140 °C / -10 to 85 °C12ODO Cap H3, H4
VisiTrace mA / RS485Optical0 to 2000 ppb-10 to 140 °C / -10 to 85 °C12ODO Cap L1
VisiWater DO P ArcOpticalup to 40 ppm0 to 60 °C12ODO Cap H20
OxyFerm FDAAmperometric10 ppb to 40 ppm0 to 130 °C4Membrane Kit FDA, CIP and standard
OxyGold GAmperometric1 ppb to 40 ppm0 to 130 °C12OxyGold Membrane Kit and Oxylyte G
OxyGold BAmperometric8 ppb to 40 ppm0 to 100 °C12OxyGold Membrane Kit and Oxylyte B
OxysensAmperometric40 ppb to 40 ppm0 to 60 °C4No membrane or electrolyte change

Optical or amperometric: how to choose

VisiFerm and VisiTrace optical sensors

The VisiFerm sensor is delivered ready to use without the need for polarization. It is flow independent and has no CO2 fouling issues. VisiFerm mA is a 2-wire sensor with 4-20 mA and HART output for use in explosive environments (ATEX / IECEx). The VisiTrace sensors, with the special ODO Cap L1, are designed to measure ppb levels of dissolved oxygen, and they are listed for power plants. Only the ODO Cap is renewed periodically; there is no liquid electrolyte to refill.

OxyGold G and OxyGold B

OxyGold G is designed for processes in which very small amounts of oxygen have to be traced, such as in the pharmaceutical or microelectronics industry and in boiler feed water. It is suitable for use at high temperatures and high pressures during sterilization and CIP, and its cathode can be replaced (REF 237395 for 120 mm VP6, REF 237396 for 225 mm VP6, REF 243110 and REF 243111 for the Arc versions).

OxyGold B (REF 237180 for 120 mm, REF 237185 for 225 mm) is the sensor for applications that contain carbon dioxide, such as the production of beer, sparkling wine and soft drinks, and for CO2 recovery. It works with a polarization voltage of 0 mV and Oxylyte B electrolyte, so there is no cross-sensitivity with CO2. According to the operating instructions, the electrolyte fill is 1.5 mL and the sensor must not be tightened above 1.5 Nm in the housing.

Oxysens

Oxysens (REF 237150, 120 mm shaft, 5 m fixed cable) is designed for water applications such as wastewater treatment, swimming pools and fish farms. The membrane and the electrolyte do not need to be replaced, the response time is fast and it is insensitive to soiling. For open channels and streams, the Immersing Set (REF 237158) sheaths and protects the sensor while it is immersed.

Original Hamilton DO accessories

AccessoryDescriptionCompatible sensorREF
ODO Cap H0 / H2 / H3 / H4Optical measuring capVisiFerm RS485 (H0, H2, H3, H4); VisiFerm mA (H3, H4)H0, H2, H3, H4
ODO Cap L1 / H20Trace oxygen cap (L1) and water/wastewater cap (H20)VisiTrace (L1); VisiWater DO P Arc (H20)L1, H20
OxyFerm Membrane Kit3 membrane bodies, Oxylyte, pipette, spare o-ring, polishing stripOxyFerm237123
Membrane Kit FDA3 FDA membrane bodies with rounded designOxyFerm FDA237140
Membrane Kit CIP3 membrane bodies for CIP cleaningsOxyFerm CIP / FDA237126
OxyGold Membrane Kit3 membrane bodies, pipette, spare o-ring (electrolyte ordered separately)OxyGold G, OxyGold B237135
Oxylyte electrolytesOxylyte, Oxylyte G, Oxylyte BOxyFerm / OxyGold G / OxyGold B237118 / 237139 / 237138
Polarization Module T / G / BPrepares replacement sensors for immediate useOxyFerm (T), OxyGold G (G), OxyGold B (B)237370 / 237350 / 237360
Replacement cathodeReplaceable cathodeOxyFerm / OxyGold G / OxyGold B237306 / 237427 / 237437
Autoclavation Cap / Immersing SetConnector protection for autoclavation / protection for 120 mm sensors in channelsOxyFerm (T82) / Oxysens242000 / 237158

For the maintenance items in more detail, see Hamilton oxygen sensor accessories. For background on optical measurement, see the optical dissolved oxygen sensor guide and the guide to dissolved oxygen in boiler water. For retractable housings that allow calibration without stopping the process, see Hamilton Retractex housings.

Applications

  • CIP/SIP-compatible dissolved oxygen control in bioreactor and fermentation lines (VisiFerm, OxyFerm FDA)
  • Trace oxygen measurement in beer, sparkling wine, soft drinks and CO2 recovery plants (OxyGold B, with 0 mV polarization voltage)
  • Trace oxygen monitoring in boiler feed water and in pharmaceutical and microelectronics processes (OxyGold G, VisiTrace)
  • Dissolved oxygen monitoring in wastewater treatment and fish farms (Oxysens, VisiWater DO P Arc)

Other Hamilton products

All Hamilton products →

Send us your requirement for Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors

Describe your application; we will help you identify the right model and configuration.

Call Quote