Technical specifications

| Microlab 600 and 700 series | Positive displacement syringe pumps; dual-syringe diluters, single- and dual-syringe dispensers and continuous dispensers |
|---|---|
| Accuracy | Better than 99%, independent of the viscosity, vapor pressure and temperature of the liquid (Microlab 600 and 700) |
| Accuracy and precision | ±1% accuracy, ±0.2% precision (pump specifications of Microlab 600 and 700) |
| Dilution ratio | Up to 1:50,000 in a single step with the dual-syringe diluter |
| Dispense volume | Microlab 600: 500 nL to 50 mL. Microlab 700: up to 50 mL (see the note below the series comparison) |
| Syringes | 12 sizes from 10 µL to 50 mL; Bubble Free Prime (BFP) syringes; SaltLine syringes for high-salt solutions |
| Controller levels | Microlab 600: Basic and Advanced (5.7 inch touchscreen). Microlab 700: Advanced and Premium (7 inch touchscreen) |
| Compliance | Security options and log files that conform to 21 CFR Part 11 and FDA GMP/GLP requirements: Microlab 600 Advanced controller with LyncStore, and Microlab 700 |
| Calibration and certifications | Factory tested and traceable to N.I.S.T. standards; CE (Microlab 600 also CSA) |
| Standalone syringe pumps | ML630 (single syringe) and ML635 (dual syringe), controlled externally over Ethernet (.NET 2.0 API) or RS-232 |
Hamilton Microlab 600 and Microlab 700 are semi-automated benchtop liquid handlers built on positive displacement syringe pumps. They are configured as dual-syringe diluters, single- or dual-syringe dispensers and continuous dispensers, and they handle the tasks that are too small to automate and too large to do reliably by hand. The positive displacement system provides better than 99% accuracy, independent of the viscosity, vapor pressure and temperature of the liquid, and the inert fluid path (borosilicate, PTFE and CTFE) minimizes sample carryover. Mikron Proses (Üsküdar, Istanbul) is one of Hamilton’s distributors in Turkey and provides application consulting on model selection, syringes and accessories.
Diluters · Dispensers · Syringe pumps → Send us your requirement
Microlab 600 and 700 compared
| Microlab 600 | Microlab 700 | |
|---|---|---|
| Controller levels | Basic, Advanced | Advanced, Premium |
| Screen | 5.7 inch touchscreen (640 × 480) | 7 inch touchscreen (1280 × 800) |
| Models | 3 diluter models, 6 dispenser models | 3 diluter models, 6 dispenser models |
| Accuracy / precision | ±1% / ±0.2% | ±1% / ±0.2% |
| Single-step dilution | Up to 1:50,000 | Up to 1:50,000 |
| Dispense volume | 500 nL to 50 mL | Up to 50 mL (see note) |
| Syringes | 10 µL to 50 mL; Bubble Free Prime and SaltLine | 10 µL to 50 mL; Bubble Free Prime and SaltLine |
| Software | Basic: Quick Start screen for standard dilutions and dispensing. Advanced: methods with air gaps, washing and repetitive dispensing, Wizards, Favorites, custom methods, more than 1,000 methods, log files, 10 languages | Wizards (including Dry Weight Dilution with a connected balance), Favorites, custom methods, audit trail viewer, maintenance reminders, GMP/GLP printer menu, 6 languages |
| 21 CFR Part 11 and GMP/GLP | Advanced: security options and LyncStore log management | Security settings (multiple administrators, PDF signatures, automatic sign-out); LyncStore 700 and REST-API only in Premium |
| Connectivity | Ethernet 10/100 | Ethernet, Wi-Fi, USB; Premium: REST-API for LIMS and mobile devices |
| Calibration and certification | N.I.S.T. traceable; CE, CSA | N.I.S.T. traceable; CE |
| Upgrade | Basic to Advanced with a software kit (P/N 61500-02) | Advanced to Premium with an activation key (P/N 10101502) |
Note: the Microlab 700 brochure gives the dispense volume range as 100 nL to 50 mL in its text and as 1.0 µL to 50 mL in its specification table, so no lower limit is stated here. Sources: Microlab 600 Catalog Rev J and Microlab 700 Brochure 10108577.
Diluter models
A dual-syringe diluter takes the sample with the small syringe and the diluent with the large syringe, and makes a high-ratio dilution in a single step. The diluent washes the line between samples, which minimizes carryover in sensitive techniques such as AA, ICP, HPLC and GC.
| Model | Series | Controller | Hand probe |
|---|---|---|---|
| ML615-DIL | 600 | Basic | Concorde |
| ML625-DIL | 600 | Advanced | Concorde |
| ML625-DTHP | 600 | Advanced | Disposable Tip Hand Probe (DTHP) |
| ML715-DIL (10103468) | 700 | Advanced | Concorde |
| ML725-DIL (10103471) | 700 | Premium | Concorde |
| ML725-DTHP (10103470) | 700 | Premium | Disposable Tip Hand Probe (DTHP) |
With the Disposable Tip Hand Probe, the sample is drawn into a disposable ClickSure tip (50 µL and 1 mL, 960 tips per rack or bulk), which eliminates carryover.
Dispenser models
There are three configurations: a single-syringe dispenser, a dual-syringe dispenser and a continuous dispenser, in which one syringe fills while the other dispenses so that the instrument is always ready. Built-in Wizards cover aliquot dispensing, serial dispensing, titration and pipetting.
| Model | Series | Configuration | Controller |
|---|---|---|---|
| ML610-DIS | 600 | Single syringe | Basic |
| ML615-DIS | 600 | Dual syringe | Basic |
| ML615-CNT | 600 | Continuous | Basic |
| ML620-DIS | 600 | Single syringe | Advanced |
| ML625-DIS | 600 | Dual syringe | Advanced |
| ML625-CNT | 600 | Continuous | Advanced |
| ML710-DIS (10103458) | 700 | Single syringe | Advanced |
| ML715-DIS (10103461) | 700 | Dual syringe | Advanced |
| ML715-CNT (10103465) | 700 | Continuous | Advanced |
| ML720-DIS (10103460) | 700 | Single syringe | Premium |
| ML725-DIS (10103464) | 700 | Dual syringe | Premium |
| ML725-CNT (10103467) | 700 | Continuous | Premium |
If no syringes are selected when ordering, the -DIS models ship with 1 mL syringes and, in the Microlab 700 brochure, the -CNT models with 10 mL syringes; diluters ship with 2.5 mL and 250 µL syringes.
Standalone syringe pumps
The ML630 (single syringe) and ML635 (dual syringe) are controlled from an external system and are listed with the same codes in the Microlab 600 catalog and the Microlab 700 brochure. If no syringe is selected, they ship with 1 mL syringes.
- Ethernet gives access to the full details of the pump and remote control; it is programmed through the .NET 2.0 application programming interface, for example from Visual C#, Visual Basic or LabVIEW. It suits remote dispensing in restricted environments.
- RS-232 is the choice if the control device is a programmable logic controller, if a platform other than Windows with .NET 2.0 is used, or if an older RS-232 device such as the Microlab 500 or a Modular Valve Positioner is involved.
For analytical syringes and needles, see Hamilton precision syringes, needles and chromatography accessories.
Applications
- Sample dilution for analytical techniques such as AA, ICP, HPLC, GC and liquid scintillation
- Preparation of standard series and standard addition in analytical chemistry
- Pharmaceutical, forensic, environmental analysis, mining and manufacturing laboratories (industries named in the Microlab 600 catalog)
- Food and beverage, dairy and textile laboratories (additional industries named in the Microlab 700 brochure)
Datasheets and manuals
- Microlab 700 Series Brochure (model codes, specifications) Catalog · PDF
- Microlab 600 Catalog (Rev J: models, software, specifications) Catalog · PDF
Documents were last compared with the manufacturer's source on 2026-10-31.
Other Hamilton products
- Hamilton Arc Peripherals and ArcAir Software (Arc View Mobile, Arc Wi Pivot, Arc USB, ArcAir) Online Measurement and Automation Systems
- Hamilton ChemoTrode pH Sensors for Aggressive Media pH and ORP Sensors
- Hamilton CO2NTROL Solid-State Optical Dissolved CO2 Sensor Online Measurement and Automation Systems
- Hamilton DuraCal pH Buffer, ORP and Conductivity Calibration Solutions Online Measurement and Automation Systems
- Hamilton EasyControl pH and ORP Sensors pH and ORP Sensors
- Hamilton Bioprocess pH Sensors (EasyFerm Plus, EasyFerm Bio and OneFerm) pH and ORP Sensors
- Hamilton GlucoSense In-Situ Optical Glucose Sensor for Bioreactors Online Measurement and Automation Systems
- Hamilton Cell Density Sensors (InCyte / Dencytee) Online Measurement and Automation Systems
- Hamilton Conductivity Sensors Conductivity Sensors
- Hamilton InchTrode pH Electrode pH and ORP Sensors
- Hamilton Incyte Arc Viable Cell Density Sensor Online Measurement and Automation Systems
- Hamilton IonoTrode pH Electrode for Low-Conductivity Media pH and ORP Sensors
- Hamilton Calibration Solutions (DuraCal pH and ORP Buffers and Conductivity Standards) Online Measurement and Automation Systems
- Hamilton Laboratory pH and ORP Electrodes (GLP Series) Online Measurement and Automation Systems
- Hamilton Process Analytics, Liquid Handling and Laboratory Solutions Online Measurement and Automation Systems
- Hamilton MecoTrode pH Electrode Hamilton pH and ORP Process Sensors
- Hamilton OEM Sensors and Sensor Accessories Online Measurement and Automation Systems
- Hamilton Oxygen Sensor Accessories (Oxylyte Electrolyte, Membrane Kits, Calibration Station) Hamilton Dissolved Oxygen Sensors
- Hamilton OneFerm pH Single-Use pH Sensor Hamilton pH and ORP Process Sensors
- Hamilton Polilyte Plus pH Sensors Hamilton pH and ORP Process Sensors
- Hamilton Process Fittings and Flow Cells (FlexiFit, StatoFlex, FlowChamber, FlowCell, FlexiFlow, MasterFit) Online Measurement and Automation Systems
- Hamilton Retractex Retractable Sensor Housings Online Measurement and Automation Systems
- Hamilton Precision Syringes, Needles and Chromatography Accessories Online Measurement and Automation Systems
- Hamilton VisiFerm DO, OxyFerm, OxyGold and Oxysens Dissolved Oxygen Sensors Hamilton Dissolved Oxygen Sensors
Send us your requirement for Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps
Describe your application; we will help you identify the right model and configuration.