Skip to main content
Üsküdar / İstanbul
Hamilton

Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps

Hamilton Microlab 600 and 700 are semi-automated benchtop liquid handlers: positive displacement syringe pumps configured as dual-syringe diluters, single- or dual-syringe and continuous dispensers, plus the standalone ML630 and ML635 syringe pumps.

Send us your requirement

Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Hamilton Microlab 700 diluter and dispenser with touchscreen controller
Microlab 600 and 700 seriesPositive displacement syringe pumps; dual-syringe diluters, single- and dual-syringe dispensers and continuous dispensers
AccuracyBetter than 99%, independent of the viscosity, vapor pressure and temperature of the liquid (Microlab 600 and 700)
Accuracy and precision±1% accuracy, ±0.2% precision (pump specifications of Microlab 600 and 700)
Dilution ratioUp to 1:50,000 in a single step with the dual-syringe diluter
Dispense volumeMicrolab 600: 500 nL to 50 mL. Microlab 700: up to 50 mL (see the note below the series comparison)
Syringes12 sizes from 10 µL to 50 mL; Bubble Free Prime (BFP) syringes; SaltLine syringes for high-salt solutions
Controller levelsMicrolab 600: Basic and Advanced (5.7 inch touchscreen). Microlab 700: Advanced and Premium (7 inch touchscreen)
ComplianceSecurity options and log files that conform to 21 CFR Part 11 and FDA GMP/GLP requirements: Microlab 600 Advanced controller with LyncStore, and Microlab 700
Calibration and certificationsFactory tested and traceable to N.I.S.T. standards; CE (Microlab 600 also CSA)
Standalone syringe pumpsML630 (single syringe) and ML635 (dual syringe), controlled externally over Ethernet (.NET 2.0 API) or RS-232

Hamilton Microlab 600 and Microlab 700 are semi-automated benchtop liquid handlers built on positive displacement syringe pumps. They are configured as dual-syringe diluters, single- or dual-syringe dispensers and continuous dispensers, and they handle the tasks that are too small to automate and too large to do reliably by hand. The positive displacement system provides better than 99% accuracy, independent of the viscosity, vapor pressure and temperature of the liquid, and the inert fluid path (borosilicate, PTFE and CTFE) minimizes sample carryover. Mikron Proses (Üsküdar, Istanbul) is one of Hamilton’s distributors in Turkey and provides application consulting on model selection, syringes and accessories.

Diluters · Dispensers · Syringe pumps → Send us your requirement

Microlab 600 and 700 compared

Microlab 600Microlab 700
Controller levelsBasic, AdvancedAdvanced, Premium
Screen5.7 inch touchscreen (640 × 480)7 inch touchscreen (1280 × 800)
Models3 diluter models, 6 dispenser models3 diluter models, 6 dispenser models
Accuracy / precision±1% / ±0.2%±1% / ±0.2%
Single-step dilutionUp to 1:50,000Up to 1:50,000
Dispense volume500 nL to 50 mLUp to 50 mL (see note)
Syringes10 µL to 50 mL; Bubble Free Prime and SaltLine10 µL to 50 mL; Bubble Free Prime and SaltLine
SoftwareBasic: Quick Start screen for standard dilutions and dispensing. Advanced: methods with air gaps, washing and repetitive dispensing, Wizards, Favorites, custom methods, more than 1,000 methods, log files, 10 languagesWizards (including Dry Weight Dilution with a connected balance), Favorites, custom methods, audit trail viewer, maintenance reminders, GMP/GLP printer menu, 6 languages
21 CFR Part 11 and GMP/GLPAdvanced: security options and LyncStore log managementSecurity settings (multiple administrators, PDF signatures, automatic sign-out); LyncStore 700 and REST-API only in Premium
ConnectivityEthernet 10/100Ethernet, Wi-Fi, USB; Premium: REST-API for LIMS and mobile devices
Calibration and certificationN.I.S.T. traceable; CE, CSAN.I.S.T. traceable; CE
UpgradeBasic to Advanced with a software kit (P/N 61500-02)Advanced to Premium with an activation key (P/N 10101502)

Note: the Microlab 700 brochure gives the dispense volume range as 100 nL to 50 mL in its text and as 1.0 µL to 50 mL in its specification table, so no lower limit is stated here. Sources: Microlab 600 Catalog Rev J and Microlab 700 Brochure 10108577.

Diluter models

A dual-syringe diluter takes the sample with the small syringe and the diluent with the large syringe, and makes a high-ratio dilution in a single step. The diluent washes the line between samples, which minimizes carryover in sensitive techniques such as AA, ICP, HPLC and GC.

ModelSeriesControllerHand probe
ML615-DIL600BasicConcorde
ML625-DIL600AdvancedConcorde
ML625-DTHP600AdvancedDisposable Tip Hand Probe (DTHP)
ML715-DIL (10103468)700AdvancedConcorde
ML725-DIL (10103471)700PremiumConcorde
ML725-DTHP (10103470)700PremiumDisposable Tip Hand Probe (DTHP)

With the Disposable Tip Hand Probe, the sample is drawn into a disposable ClickSure tip (50 µL and 1 mL, 960 tips per rack or bulk), which eliminates carryover.

Dispenser models

There are three configurations: a single-syringe dispenser, a dual-syringe dispenser and a continuous dispenser, in which one syringe fills while the other dispenses so that the instrument is always ready. Built-in Wizards cover aliquot dispensing, serial dispensing, titration and pipetting.

ModelSeriesConfigurationController
ML610-DIS600Single syringeBasic
ML615-DIS600Dual syringeBasic
ML615-CNT600ContinuousBasic
ML620-DIS600Single syringeAdvanced
ML625-DIS600Dual syringeAdvanced
ML625-CNT600ContinuousAdvanced
ML710-DIS (10103458)700Single syringeAdvanced
ML715-DIS (10103461)700Dual syringeAdvanced
ML715-CNT (10103465)700ContinuousAdvanced
ML720-DIS (10103460)700Single syringePremium
ML725-DIS (10103464)700Dual syringePremium
ML725-CNT (10103467)700ContinuousPremium

If no syringes are selected when ordering, the -DIS models ship with 1 mL syringes and, in the Microlab 700 brochure, the -CNT models with 10 mL syringes; diluters ship with 2.5 mL and 250 µL syringes.

Standalone syringe pumps

The ML630 (single syringe) and ML635 (dual syringe) are controlled from an external system and are listed with the same codes in the Microlab 600 catalog and the Microlab 700 brochure. If no syringe is selected, they ship with 1 mL syringes.

  • Ethernet gives access to the full details of the pump and remote control; it is programmed through the .NET 2.0 application programming interface, for example from Visual C#, Visual Basic or LabVIEW. It suits remote dispensing in restricted environments.
  • RS-232 is the choice if the control device is a programmable logic controller, if a platform other than Windows with .NET 2.0 is used, or if an older RS-232 device such as the Microlab 500 or a Modular Valve Positioner is involved.

For analytical syringes and needles, see Hamilton precision syringes, needles and chromatography accessories.

Applications

  • Sample dilution for analytical techniques such as AA, ICP, HPLC, GC and liquid scintillation
  • Preparation of standard series and standard addition in analytical chemistry
  • Pharmaceutical, forensic, environmental analysis, mining and manufacturing laboratories (industries named in the Microlab 600 catalog)
  • Food and beverage, dairy and textile laboratories (additional industries named in the Microlab 700 brochure)

Other Hamilton products

All Hamilton products →

Send us your requirement for Hamilton Microlab 600 and 700 Diluters, Dispensers and Syringe Pumps

Describe your application; we will help you identify the right model and configuration.

Call Quote