Skip to main content
Üsküdar / İstanbul
Hamilton

Hamilton Laboratory pH and ORP Electrodes (GLP Series)

Hamilton GLP laboratory pH and ORP electrodes, each supplied with an indelible serial number and an individual test certificate. The range includes Polilyte Lab, Single Pore Glass, BioTrode, FoodTrode, SlimTrode and Liq-Glass electrodes, S7 cables, electrolytes and DuraCal buffers. Mikron Proses is one of Hamilton's distributors in Turkey.

Send us your requirement

Hamilton Laboratory pH and ORP Electrodes (GLP Series) — describe your application and we will help you identify the right model and configuration together.

Technical specifications

Hamilton GLP laboratory pH and ORP electrode family
Measuring rangepH 0 to 14; ORP models ±2000 mV
Temperature range by modelLiq-Glass and FoodTrode -10 to 100 °C; Polilyte Lab and FlushTrode -10 to 80 °C; Gel-Glass -10 to 60 °C; Single Pore Glass, BioTrode, SlimTrode, MiniTrode, SpinTrode and TipTrode 0 to 100 °C; Polyplast, Double Pore, FillTrode and FlaTrode 0 to 60 °C
Diaphragm technologiesSingle Pore (a capillary pore about 200 times larger in cross-section than the pores of a ceramic diaphragm), Double Pore (2 Single Pores), ceramic diaphragms (1 or 3), ring diaphragm and sleeve diaphragm (FlushTrode)
Reference systems and electrolytesEveref and Everef-B reference systems; Polisolve polymer electrolyte (acrylamide free); Protelyte, Skylyte-CL and 3 M KCl
Small sample volumesBioTrode and MiniTrode with a 3 mm shaft and an immersion depth of only 7 mm, for very small volumes such as vials and microtiter plates; FlaTrode with a flat membrane for surfaces and single drops
Connector and IP ratingS7 connector head with a high-quality seal between electrode head and cable (IP 68), or fixed cables with BNC, DIN or Lemo plugs and a Pt1000 or NTC 30 kΩ temperature sensor
GLP traceabilityEach electrode carries an indelible serial number and comes with an individual test certificate that lists the measured millivolt values

Hamilton GLP laboratory pH and ORP electrodes are combination electrodes for daily laboratory work in GLP environments. Every electrode has an indelible serial number printed on the shaft and comes with an individual test certificate that lists the measured millivolt values, which supports traceability in your documentation. Mikron Proses (Üsküdar, Istanbul) is one of Hamilton’s distributors in Turkey. We supply laboratory electrodes, S7 cables, electrolytes and DuraCal pH buffers, and we provide application consulting on matching an electrode to your benchtop pH meter and sample type.

Laboratory electrodes · S7 cables · Electrolytes → Send us your requirement

Electrode selection by sample type

The model codes (REF) and technical limits below are taken from the Hamilton GLP Laboratory Electrodes Catalog (electrode pages and the specifications table).

Application groupModel and main REFElectrolyte and reference systemDiaphragm and shaftTemperature and typical samples
Ion-weak, organic and difficult samplesPolilyte Lab (REF 238403; temperature models 242058, 242059, 242060, 242062)Polisolve (maintenance-free); Everef-BSingle Pore; glass shaft-10 to 80 °C; emulsions, suspensions, ion-weak media
General high-accuracy laboratory workSingle Pore Glass (REF 238160)Skylyte-CL (refillable, REF 242080); EverefSingle Pore; glass shaft0 to 100 °C; emulsions, ion-weak media, general laboratory applications
Protein and very small volumesBioTrode (REF 238140)Protelyte (refillable, REF 238038); EverefCeramic diaphragm; 3 mm shaft, 7 mm immersion depth0 to 100 °C; solutions containing protein, microtiter plates
Test tubes, vials and NMR tubesSlimTrode (REF 238150), MiniTrode (REF 238100), SpinTrode (REF 238197)3 M KCl (refillable); EverefCeramic diaphragm; shaft below 6 mm (SlimTrode), 3 mm (MiniTrode, SpinTrode)0 to 100 °C; test tubes (SlimTrode), vials (MiniTrode), NMR tubes (SpinTrode)
Foodstuffs with proteinFoodTrode (REF 238285)Protelyte (refillable); Everef3 ceramic diaphragms; glass shaft-10 to 100 °C; media containing proteins
Solid and semisolid samplesTipTrode (REF 238080); Double Pore (REF 238400)TipTrode: Protelyte, Everef. Double Pore: Polisolve, Ag/AgClTipTrode: ceramic diaphragm. Double Pore: 2 Single PoresTipTrode 0 to 100 °C; Double Pore 0 to 60 °C; puncture electrodes, Double Pore for cheese and meat
Flat surfacesFlaTrode (REF 238401)Polisolve (maintenance-free); EverefRing diaphragm; flat glass membrane; plastic shaft0 to 60 °C; surfaces such as paper and agar plates
Viscous samples and very low conductivityFlushTrode (REF 238060)3 M KCl (refillable, REF 238036); EverefSleeve (ground sleeve) diaphragm; glass shaft-10 to 80 °C; viscous samples, ion-weak media, cosmetics
Standard general laboratory useLiq-Glass (REF 238000), Gel-Glass (REF 238025)Liq-Glass: 3 M KCl (refillable); Everef. Gel-Glass: gel; Ag/AgClCeramic diaphragm; glass shaftLiq-Glass -10 to 100 °C; Gel-Glass -10 to 60 °C; routine aqueous solutions
Plastic shaft (portable and water applications)Polyplast (REF 238380; BNC 238381; temperature models 242050, 242051, 242052) and FillTrode (REF 242064)Polisolve (maintenance-free); Ag/AgCl (Polyplast), Everef (FillTrode)Single Pore (Polyplast), ring diaphragm (FillTrode); plastic shaft0 to 60 °C; water and sewage
Laboratory ORP (redox)Liq-Glass ORP (REF 238145), Polyplast ORP (REF 238385; BNC 238384)Liq-Glass ORP: 3 M KCl; Everef. Polyplast ORP: Polisolve; Ag/AgClPlatinum; 3 ceramic diaphragms (Liq-Glass ORP) or Single Pore (Polyplast ORP)±2000 mV; Liq-Glass ORP -10 to 100 °C, Polyplast ORP 0 to 60 °C

For samples containing protein, the catalog recommends replacing the 3 M KCl in the refillable electrodes with Protelyte (REF 238038).

S7 cables, electrolytes and care solutions

Hamilton electrodes with an S7 head are connected to the pH meter with a 3 mm coaxial S7 cable. The equipment-side plug is chosen to fit the pH meter. All BNC plugs have a moveable protective cover that protects the plug from fluid splashes.

Product groupDescription and length or volumeHamilton order code (REF)Used with
S7 / BNC cable1 m, 3 m or 5 mREF 355173 (1 m), 355176 (3 m), 355178 (5 m)pH/ORP meters with a BNC input
S7 / DIN cable1 m, 3 m or 5 mREF 355174 (1 m), 355177 (3 m), 355179 (5 m)pH/ORP meters with a DIN input
S7 / Lemo cable1 mREF 355175pH/ORP meters with a Lemo input
3 M KCl electrolyte100 mL or 500 mLREF 238036 (100 mL), 238936 (500 mL)Liq-Glass, FlushTrode, SlimTrode, MiniTrode, SpinTrode, Liq-Glass ORP
Skylyte-CL electrolyte100 mLREF 242080Single Pore Glass
Protelyte electrolyte100 mLREF 238038BioTrode, FoodTrode, TipTrode
Storage solution500 mL, acid-buffered; also regenerates the electrodeREF 238931Storage of the electrodes
Cleaning solution setCleaning Solution A, Cleaning Solution B and storage solution; 15 to 30 minutes in each solutionREF 238290Removing contamination from the pH glass and the diaphragm

Applications

  • pH and ORP analysis in GLP laboratory environments
  • Foodstuffs: media containing proteins (FoodTrode) and solid and semisolid samples such as cheese and meat (TipTrode, Double Pore)
  • Biochemistry, protein-containing solutions and very small sample volumes in vials, test tubes and microtiter plates (BioTrode, SlimTrode, MiniTrode, SpinTrode)
  • Ion-weak media, emulsions, suspensions and viscous samples (Polilyte Lab, Single Pore Glass, FlushTrode)

Datasheets and manuals

Documents were last compared with the manufacturer's source on 2026-10-30.

Other Hamilton products

All Hamilton products →

Send us your requirement for Hamilton Laboratory pH and ORP Electrodes (GLP Series)

Describe your application; we will help you identify the right model and configuration.